{"id":306336,"date":"2026-01-02T16:13:47","date_gmt":"2026-01-02T07:13:47","guid":{"rendered":"https:\/\/ksensors.co.kr\/product\/saintbond-lcx6006-multi-axis-force-sensor-6-axis-force-torque-sensor-load-cell\/"},"modified":"2026-01-02T16:13:47","modified_gmt":"2026-01-02T07:13:47","slug":"saintbond-lcx6006-multi-axis-force-sensor-6-axis-force-torque-sensor-load-cell","status":"publish","type":"product","link":"https:\/\/ksensors.co.kr\/en\/product\/saintbond-lcx6006-multi-axis-force-sensor-6-axis-force-torque-sensor-load-cell\/","title":{"rendered":"SAINTBOND \/ LCX6006 Multi-axis Force Sensor 6 Axis Force Torque Sensor Load Cell"},"content":{"rendered":"<h1 class=\"this-description-name\">LCX6006 Multi-axis Force Sensor 6 Axis Force Torque Sensor Load Cell<\/h1>\n<p><strong><a>Product Description<\/a><\/strong><\/p>\n<div class=\"detial-cont-tabscont\">\n<div class=\"fix prodDesc\">\n<div class=\"prodDetail-editor-container \">\n<p>&nbsp;<\/p>\n<p><img decoding=\"async\" class=\" lazyloaded\" title=\"\u56fe\u72471\" src=\"https:\/\/ksensors.co.kr\/wp-content\/uploads\/2026\/01\/55_tupian1.png\" alt=\"\u56fe\u72471\" data-original=\"\/\/ilrorwxhklojlp5p.ldycdn.com\/cloud\/liBpoKmlliSRnjkljmmkip\/tupian1.png\" \/><\/p>\n<p><strong>Product Introduction:<\/strong><\/p>\n<p>\u25ceBased on the principle of strain electrical measurement;<\/p>\n<p>\u25ceEmbedded high-precision data acquisition and processing circuit;<\/p>\n<p>\u25ceDirectly output the force and torque after decoupling;<\/p>\n<p>\u25ceDerived from aerospace testing technology;<\/p>\n<p>\u25ceAccuracy is better than 0.5% FS;<\/p>\n<p>\u25ceIt can be applied to small industrial robots, grinding robots, etc;<\/p>\n<p><strong>Dimension:<\/strong><\/p>\n<p><img decoding=\"async\" class=\" lazyloaded\" title=\"\u56fe\u72472\" src=\"https:\/\/ksensors.co.kr\/wp-content\/uploads\/2026\/01\/55_tupian2-1200x670.png\" alt=\"\u56fe\u72472\" data-original=\"\/\/ilrorwxhklojlp5p.ldycdn.com\/cloud\/lrBpoKmlliSRnjkljmpkip\/tupian2.png\" \/><\/p>\n<p><strong>Technical Parameter\uff1a<\/strong><\/p>\n<div class=\"sliderTable mt10 mb10 sliderTable-index0 change-to-org\">\n<div class=\"inner\">\n<table width=\"562\">\n<tbody>\n<tr class=\"firstRow\">\n<td valign=\"center\" width=\"157\">Type<\/td>\n<td valign=\"center\" width=\"103\">LCX6006A<\/td>\n<td valign=\"center\" width=\"100\">LCX6006B<\/td>\n<td valign=\"center\" width=\"97\">LCX6006C<\/td>\n<td valign=\"center\" width=\"105\">LCX6006D<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"157\">Fx,Fy (N)<\/td>\n<td valign=\"center\" width=\"103\">100<\/td>\n<td valign=\"center\" width=\"100\">200<\/td>\n<td valign=\"center\" width=\"97\">300<\/td>\n<td valign=\"center\" width=\"105\">400<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"157\">Fz (N)<\/td>\n<td valign=\"center\" width=\"103\">200<\/td>\n<td valign=\"center\" width=\"100\">400<\/td>\n<td valign=\"center\" width=\"97\">600<\/td>\n<td valign=\"center\" width=\"105\">800<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"157\">Mx,My(Nm)<\/td>\n<td valign=\"center\" width=\"103\">10<\/td>\n<td valign=\"center\" width=\"100\">18<\/td>\n<td valign=\"center\" width=\"97\">24<\/td>\n<td valign=\"center\" width=\"105\">36<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"157\">Mz(Nm)<\/td>\n<td valign=\"center\" width=\"103\">10<\/td>\n<td valign=\"center\" width=\"100\">18<\/td>\n<td valign=\"center\" width=\"97\">24<\/td>\n<td valign=\"center\" width=\"105\">36<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"157\">Dia.(mm)<\/td>\n<td valign=\"center\" width=\"103\">94<\/td>\n<td valign=\"center\" width=\"100\">94<\/td>\n<td valign=\"center\" width=\"97\">94<\/td>\n<td valign=\"center\" width=\"105\">94<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"157\">Height(mm)<\/td>\n<td valign=\"center\" width=\"103\">26<\/td>\n<td valign=\"center\" width=\"100\">26<\/td>\n<td valign=\"center\" width=\"97\">26<\/td>\n<td valign=\"center\" width=\"105\">26<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"157\">Material<\/td>\n<td colspan=\"4\" valign=\"center\" width=\"404\">Duralumin alloy<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"157\">Overload level (% FS)<\/td>\n<td valign=\"center\" width=\"103\">300<\/td>\n<td valign=\"center\" width=\"100\">300<\/td>\n<td valign=\"center\" width=\"97\">300<\/td>\n<td valign=\"center\" width=\"105\">300<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"157\">Precision (% FS)*<\/td>\n<td valign=\"center\" width=\"103\">0.1<\/td>\n<td valign=\"center\" width=\"100\">0.1<\/td>\n<td valign=\"center\" width=\"97\">0.1<\/td>\n<td valign=\"center\" width=\"105\">0.1<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"157\">Accuracy (% FS)**<\/td>\n<td valign=\"center\" width=\"103\">0.5<\/td>\n<td valign=\"center\" width=\"100\">0.5<\/td>\n<td valign=\"center\" width=\"97\">0.5<\/td>\n<td valign=\"center\" width=\"105\">0.5<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"157\">Weight (kg)<\/td>\n<td valign=\"center\" width=\"103\">0.3<\/td>\n<td valign=\"center\" width=\"100\">0.32<\/td>\n<td valign=\"center\" width=\"97\">0.34<\/td>\n<td valign=\"center\" width=\"105\">0.36<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"157\">Supply voltage (VDC)<\/td>\n<td valign=\"center\" width=\"103\">9~24<\/td>\n<td valign=\"center\" width=\"100\">9~24<\/td>\n<td valign=\"center\" width=\"97\">9~24<\/td>\n<td valign=\"center\" width=\"105\">9~24<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"157\">Operating temp. (\u2103)<\/td>\n<td valign=\"center\" width=\"103\">0~80<\/td>\n<td valign=\"center\" width=\"100\">0~80<\/td>\n<td valign=\"center\" width=\"97\">0~80<\/td>\n<td valign=\"center\" width=\"105\">0~80<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"157\">Sampling resolution (bit)<\/td>\n<td valign=\"center\" width=\"103\">24<\/td>\n<td valign=\"center\" width=\"100\">24<\/td>\n<td valign=\"center\" width=\"97\">24<\/td>\n<td valign=\"center\" width=\"105\">24<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"157\">Sampling frequency (Hz)<\/td>\n<td valign=\"center\" width=\"103\">1000<\/td>\n<td valign=\"center\" width=\"100\">1000<\/td>\n<td valign=\"center\" width=\"97\">1000<\/td>\n<td valign=\"center\" width=\"105\">1000<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"157\">Degree of protection<\/td>\n<td valign=\"center\" width=\"103\">IP64<\/td>\n<td valign=\"center\" width=\"100\">IP64<\/td>\n<td valign=\"center\" width=\"97\">IP64<\/td>\n<td valign=\"center\" width=\"105\">IP64<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"157\">Communication interface<\/td>\n<td colspan=\"4\" valign=\"center\" width=\"404\">RS422\/RS485\/MODBUS\/CAN\/EtherCAT\/EtherNET\/USB\/Analog quantity<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<p>*Accuracy; Deviation from theoretical truth value;<\/p>\n<p>**Accuracy; Repeatability deviation;<\/p>\n<p>&nbsp;<\/p>\n<div class=\"sliderTable mt10 mb10 sliderTable-index1 change-to-org\">\n<div class=\"inner\">\n<table width=\"882\">\n<tbody>\n<tr class=\"firstRow\">\n<td valign=\"top\" width=\"161\">Product name<\/td>\n<td valign=\"top\" width=\"678\">LCX6006 Multi-axis Force Sensor 6 Axis Force Torque Sensor Load Cell<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"161\">Brand<\/td>\n<td valign=\"top\" width=\"678\">SAINTBOND<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"161\">Market<\/td>\n<td valign=\"top\" width=\"678\">All over the world<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"161\">Features<\/td>\n<td valign=\"top\" width=\"678\">High precision and stable performance<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"161\">Advantage<\/td>\n<td valign=\"top\" width=\"678\">0EM\/ODM<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"161\">Sample Lead Time<\/td>\n<td valign=\"top\" width=\"678\">5~ 40Days<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"161\">Sample price<\/td>\n<td valign=\"top\" width=\"678\">The price is different according to product capacity<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"161\">Custom Design<\/td>\n<td valign=\"top\" width=\"678\">Welcome<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"161\">Form of sale<\/td>\n<td valign=\"top\" width=\"678\">Factory supply<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"detial-cont-tabscont\">\n<div class=\"fix prodDesc\">\n<div class=\"prodDetail-editor-container \">\n<div class=\"sliderTable mt10 mb10 sliderTable-index1 change-to-org\"><\/div>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>LCX6006 Multi-axis Force Sensor 6 Axis Force Torque Sensor Load Cell Product Description &nbsp; Product Introduction: \u25ceBased on the principle of strain electrical measurement; \u25ceEmbedded high-precision data acquisition and processing circuit; \u25ceDirectly output the force and torque after decoupling; \u25ceDerived from aerospace testing technology; \u25ceAccuracy is better than 0.5% FS; \u25ceIt can be applied to [&hellip;]<\/p>\n","protected":false},"featured_media":306323,"template":"","meta":[],"product_brand":[2471],"product_cat":[356],"product_tag":[784],"class_list":{"0":"post-306336","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-saintbond-2-en","7":"product_cat-multiaxis-en","8":"product_tag-6-en","10":"first","11":"instock","12":"taxable","13":"shipping-taxable","14":"product-type-simple"},"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/ksensors.co.kr\/en\/wp-json\/wp\/v2\/product\/306336","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ksensors.co.kr\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/ksensors.co.kr\/en\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":0,"href":"https:\/\/ksensors.co.kr\/en\/wp-json\/wp\/v2\/product\/306336\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ksensors.co.kr\/en\/wp-json\/wp\/v2\/media\/306323"}],"wp:attachment":[{"href":"https:\/\/ksensors.co.kr\/en\/wp-json\/wp\/v2\/media?parent=306336"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/ksensors.co.kr\/en\/wp-json\/wp\/v2\/product_brand?post=306336"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/ksensors.co.kr\/en\/wp-json\/wp\/v2\/product_cat?post=306336"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/ksensors.co.kr\/en\/wp-json\/wp\/v2\/product_tag?post=306336"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}