{"id":296660,"date":"2025-12-23T14:31:47","date_gmt":"2025-12-23T05:31:47","guid":{"rendered":"https:\/\/ksensors.co.kr\/product\/naturoll-multi-range-tension-pressure-sensor-nf202\/"},"modified":"2025-12-23T14:31:47","modified_gmt":"2025-12-23T05:31:47","slug":"naturoll-multi-range-tension-pressure-sensor-nf202","status":"publish","type":"product","link":"https:\/\/ksensors.co.kr\/en\/product\/naturoll-multi-range-tension-pressure-sensor-nf202\/","title":{"rendered":"Naturoll \/ Tension and compression stainless steel load cell NF203"},"content":{"rendered":"<h1>Tension and compression stainless steel load cell NF203<\/h1>\n<p><strong><span lang=\"EN-US\">Features<\/span><\/strong><\/p>\n<p><span lang=\"EN-US\">Tension and compression stainless steel load cell NF203\u00a0is available in various capacities ranging from\u00a0<\/span>50N,100N,200N,300N,500N,1000N,2000N up to 5000N.\u00a0The Pull pressure force transducer sensor has different sizes for different ranges. The tension pressure sensor is made of stainless steel utilizing strain gauge technology.<\/p>\n<ul>\n<li>Micro sensor, low height<\/li>\n<li>Small deformation<\/li>\n<li>Tension and compression bidirectional<\/li>\n<\/ul>\n<p data-section=\"2\"><strong><span lang=\"EN-US\">Applications<\/span><\/strong><\/p>\n<ul>\n<li><span lang=\"EN-US\">Automatic assembly<\/span><\/li>\n<li><span lang=\"EN-US\">3C product testing<\/span><\/li>\n<li>Force measurement in robot welding<\/li>\n<\/ul>\n<p><strong><span lang=\"EN-US\">Mounting Dimension<\/span><\/strong><\/p>\n<p><strong><span lang=\"EN-US\"><img fetchpriority=\"high\" decoding=\"async\" src=\"https:\/\/ksensors.co.kr\/wp-content\/uploads\/2025\/12\/e8ca6a79abd9f20574d9538fa8c7570a-539x800.jpg\" alt=\"\" width=\"337\" height=\"500\" \/><img decoding=\"async\" src=\"https:\/\/ksensors.co.kr\/wp-content\/uploads\/2025\/12\/8ae339ae1c711bbcab67d0ffe34969ec.jpg\" alt=\"\" width=\"460\" height=\"500\" \/><\/span><\/strong><\/p>\n<p><strong><span lang=\"EN-US\">Load Direction<\/span><\/strong><\/p>\n<p><strong><span lang=\"EN-US\"><img decoding=\"async\" src=\"https:\/\/ksensors.co.kr\/wp-content\/uploads\/2025\/12\/16e327d2795593a9a4a7f5bae46439fb.jpg\" alt=\"\" width=\"500\" height=\"409\" \/><\/span><\/strong><strong><span lang=\"EN-US\">Wiring Code<\/span><\/strong><\/p>\n<p><span lang=\"EN-US\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/ksensors.co.kr\/wp-content\/uploads\/2025\/12\/2cda0101374bacc3d04ae07324eac435.jpg\" alt=\"\" width=\"500\" height=\"247\" \/><\/span><strong><span lang=\"EN-US\">Specifications<\/span><\/strong><\/p>\n<div class=\"table-responsive\">\n<table border=\"1\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"150\" \/>\n<col width=\"198\" \/><\/colgroup>\n<tbody>\n<tr>\n<td class=\"xl63\" width=\"150\" height=\"33\">Specifications<\/td>\n<td class=\"xl69\" width=\"198\">Technique<\/td>\n<\/tr>\n<tr>\n<td class=\"xl70\" width=\"150\" height=\"33\">Capacity<\/td>\n<td class=\"xl71\" width=\"198\">50,100,200,300,500,1000,2000,5000N<\/td>\n<\/tr>\n<tr>\n<td class=\"xl64\" width=\"150\" height=\"33\">Rated output<\/td>\n<td class=\"xl65\" width=\"198\">2.0<span class=\"font7\">\u00b1<\/span><span class=\"font5\">10%mV\/V<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"xl64\" width=\"150\" height=\"33\">Zero balance<\/td>\n<td class=\"xl68\" width=\"198\">\u00b1<span class=\"font5\">0.05mV\/V<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"xl64\" width=\"150\" height=\"33\">Non-linearity<\/td>\n<td class=\"xl67\" width=\"198\">0.1%F.S.<\/td>\n<\/tr>\n<tr>\n<td class=\"xl64\" width=\"150\" height=\"33\">Hysteresis<\/td>\n<td class=\"xl67\" width=\"198\">0.1%F.S.<\/td>\n<\/tr>\n<tr>\n<td class=\"xl64\" width=\"150\" height=\"33\">Repeatability<\/td>\n<td class=\"xl67\" width=\"198\">0.1%F.S.<\/td>\n<\/tr>\n<tr>\n<td class=\"xl64\" width=\"150\" height=\"33\">Temp.effect on output<\/td>\n<td class=\"xl67\" width=\"198\">0.05%F.S.\/10<span class=\"font6\">\u2103<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"xl64\" width=\"150\" height=\"33\">Temp.effect on zero<\/td>\n<td class=\"xl67\" width=\"198\">0.05%F.S.\/10<span class=\"font6\">\u2103<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"xl64\" width=\"150\" height=\"33\">Input impedance<\/td>\n<td class=\"xl67\" width=\"198\">800<span class=\"font7\">~<\/span><span class=\"font5\">1100\u03a9<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"xl64\" width=\"150\" height=\"33\">Output impedance<\/td>\n<td class=\"xl67\" width=\"198\">800<span class=\"font7\">~<\/span><span class=\"font5\">1100\u03a9<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"xl64\" width=\"150\" height=\"33\">Insulation<\/td>\n<td class=\"xl66\" width=\"198\">\u2265<span class=\"font5\">5000M<\/span><span class=\"font7\">\u03a9<\/span><span class=\"font5\">\/100VDC<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"xl64\" width=\"150\" height=\"33\">Recommended excitation<\/td>\n<td class=\"xl67\" width=\"198\">10V<\/td>\n<\/tr>\n<tr>\n<td class=\"xl64\" width=\"150\" height=\"33\">Maximum excitation<\/td>\n<td class=\"xl67\" width=\"198\">15V<\/td>\n<\/tr>\n<tr>\n<td class=\"xl64\" width=\"150\" height=\"33\">Compensated temp range<\/td>\n<td class=\"xl68\" width=\"198\">&#8211;<span class=\"font5\">10<\/span><span class=\"font7\">~<\/span><span class=\"font5\">60<\/span><span class=\"font6\">\u2103<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"xl64\" width=\"150\" height=\"33\">Operation temp range<\/td>\n<td class=\"xl68\" width=\"198\">&#8211;<span class=\"font5\">20<\/span><span class=\"font7\">~<\/span><span class=\"font5\">80<\/span><span class=\"font6\">\u2103<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"xl64\" width=\"150\" height=\"33\">Safe overload<\/td>\n<td class=\"xl67\" width=\"198\">150%F.S.<\/td>\n<\/tr>\n<tr>\n<td class=\"xl64\" width=\"150\" height=\"33\">Ultimate overload<\/td>\n<td class=\"xl67\" width=\"198\">200%F.S.<\/td>\n<\/tr>\n<tr>\n<td class=\"xl64\" width=\"150\" height=\"33\">Cable size<\/td>\n<td class=\"xl67\" width=\"198\">\u03c63\u00d73000mm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<table border=\"1\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td width=\"154\" height=\"33\">Model:<\/td>\n<td width=\"291\">NF203<\/td>\n<\/tr>\n<tr>\n<td height=\"33\">Category\uff1a<\/td>\n<td>Tension\/Compression Load Cells<\/td>\n<\/tr>\n<tr>\n<td height=\"33\">Capacity:<\/td>\n<td>50,100,200,300,500,1000,2000,5000N<\/td>\n<\/tr>\n<tr>\n<td height=\"33\">Rated Output:<\/td>\n<td>2.0\u00b110%mV\/V<\/td>\n<\/tr>\n<tr>\n<td height=\"33\">Material:<\/td>\n<td>Stainless steel<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":296641,"template":"","meta":[],"product_brand":[2461],"product_cat":[342],"product_tag":[346],"class_list":{"0":"post-296660","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-naturoll-en","7":"product_cat-tension-compression-load-cells","8":"product_tag-tensile-compression-load-cell","10":"first","11":"instock","12":"taxable","13":"shipping-taxable","14":"product-type-simple"},"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/ksensors.co.kr\/en\/wp-json\/wp\/v2\/product\/296660","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ksensors.co.kr\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/ksensors.co.kr\/en\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":0,"href":"https:\/\/ksensors.co.kr\/en\/wp-json\/wp\/v2\/product\/296660\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ksensors.co.kr\/en\/wp-json\/wp\/v2\/media\/296641"}],"wp:attachment":[{"href":"https:\/\/ksensors.co.kr\/en\/wp-json\/wp\/v2\/media?parent=296660"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/ksensors.co.kr\/en\/wp-json\/wp\/v2\/product_brand?post=296660"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/ksensors.co.kr\/en\/wp-json\/wp\/v2\/product_cat?post=296660"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/ksensors.co.kr\/en\/wp-json\/wp\/v2\/product_tag?post=296660"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}