{"id":282552,"date":"2025-11-14T16:52:52","date_gmt":"2025-11-14T07:52:52","guid":{"rendered":"https:\/\/ksensors.co.kr\/?post_type=product&#038;p=282552"},"modified":"2025-12-05T14:39:05","modified_gmt":"2025-12-05T05:39:05","slug":"xjcsensor-tension-and-compression-load-cell-x-l08","status":"publish","type":"product","link":"https:\/\/ksensors.co.kr\/en\/product\/xjcsensor-tension-and-compression-load-cell-x-l08\/","title":{"rendered":"Xjcsensor \/ X-L08 \/ Tension and Compression Load Cell"},"content":{"rendered":"<div class=\"matter\">\n<div class=\"title f_48 wow fadeInUp animated\"><strong>Technical Parameter<\/strong><\/div>\n<div class=\"content wow fadeInUp animated\">\n<table width=\"100%\">\n<tbody>\n<tr>\n<td>Capacity(Optional)<\/td>\n<td>50kg, 100kg, 200kg, 500kg, 1t, 2t, 5t, 7t, 10t, 20t, 30t<\/td>\n<td>Material<\/td>\n<td>Alloy steelStainless steel<\/td>\n<\/tr>\n<tr>\n<td>Nonlinearity<\/td>\n<td>\u22640.1%F.S.<\/td>\n<td>Rated output<\/td>\n<td>2.0\u00b10.2mV\/V<\/td>\n<\/tr>\n<tr>\n<td>Recommended excitation<\/td>\n<td>5-10VDC<\/td>\n<td>Maximum excitation<\/td>\n<td>10V DC<\/td>\n<\/tr>\n<tr>\n<td>Protection class<\/td>\n<td>IP66<\/td>\n<td>Compensated temp range<\/td>\n<td>-10~40\u2103<\/td>\n<\/tr>\n<tr>\n<td>Hysteresis<\/td>\n<td>\u22640.05% F.S.<\/td>\n<td>Operating temp range<\/td>\n<td>-20~80\u2103<\/td>\n<\/tr>\n<tr>\n<td>Repeatability<\/td>\n<td>\u22640.05% F.S.<\/td>\n<td>Insulation<\/td>\n<td>\u22655000M\u03a9\/100VDC<\/td>\n<\/tr>\n<tr>\n<td>Input impedance<\/td>\n<td>750\u00b150\u03a9<\/td>\n<td>Output impedance<\/td>\n<td>700\u00b110\u03a9<\/td>\n<\/tr>\n<tr>\n<td>Creep (30min)<\/td>\n<td>\u2264 0.05% F.S.<\/td>\n<td>Temp effect on output<\/td>\n<td>\u2264 0.05% F.S.\/10\u2103<\/td>\n<\/tr>\n<tr>\n<td>Zero balance<\/td>\n<td>\u00b1 2% F.S.<\/td>\n<td>Temp effect on zero<\/td>\n<td>\u22640.05% F.S.\/10\u2103<\/td>\n<\/tr>\n<tr>\n<td>Safe load limit<\/td>\n<td>150%F.S.<\/td>\n<td>Ultimate load limit<\/td>\n<td>200%F.S.<\/td>\n<\/tr>\n<tr>\n<td>Cable size<\/td>\n<td>\u00d85x3m<\/td>\n<td>Fatigue life<\/td>\n<td>Full scale more than 1 million times<\/td>\n<\/tr>\n<tr>\n<td>Cable connection<\/td>\n<td colspan=\"3\">Ex+: Red; Ex-:Black; Sig+: Green; Sig-:White<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<div class=\"matter\">\n<div><\/div>\n<div class=\"title f_48 wow fadeInUp animated\"><strong>Dimension &amp; Capacity<\/strong><\/div>\n<div class=\"content wow fadeInUp animated\">\n<p><img decoding=\"async\" src=\"https:\/\/ksensors.co.kr\/wp-content\/uploads\/2025\/11\/1758616932610879.jpg-774x800.webp\" alt=\"pic-3\" \/><\/p>\n<table width=\"100%\">\n<tbody>\n<tr>\n<td>Capacity<\/td>\n<td>D<\/td>\n<td>D1<\/td>\n<td>D2<\/td>\n<td>H<\/td>\n<td>H1<\/td>\n<td>T<\/td>\n<td>T1<\/td>\n<td>T2<\/td>\n<td>H2<\/td>\n<\/tr>\n<tr>\n<td>50\/100\/200\/500kg<\/td>\n<td>88<\/td>\n<td>72<\/td>\n<td>22<\/td>\n<td>34<\/td>\n<td>31<\/td>\n<td>M12*1.75<\/td>\n<td>8*\u03a67<\/td>\n<td>8*\u03a611<\/td>\n<td>7.2<\/td>\n<\/tr>\n<tr>\n<td>1\/2\/5\/7t<\/td>\n<td>105<\/td>\n<td>89<\/td>\n<td>32<\/td>\n<td>37<\/td>\n<td>34<\/td>\n<td>M16*1.5<\/td>\n<td>8*\u03a67<\/td>\n<td>8*\u03a611<\/td>\n<td>7.2<\/td>\n<\/tr>\n<tr>\n<td>10\/15\/20t<\/td>\n<td>120.6<\/td>\n<td>101.8<\/td>\n<td>39<\/td>\n<td>53.5<\/td>\n<td>41<\/td>\n<td>M32*1.5<\/td>\n<td>8*\u03a69<\/td>\n<td>8*\u00d81 4<\/td>\n<td>10.5<\/td>\n<\/tr>\n<tr>\n<td>30t<\/td>\n<td>141<\/td>\n<td>116.8<\/td>\n<td>50.4<\/td>\n<td>57.2<\/td>\n<td>50.8<\/td>\n<td>M40*1.5<\/td>\n<td>8*\u00d811<\/td>\n<td>8*\u00d81 8<\/td>\n<td>11<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<div class=\"matter\">\n<div><\/div>\n<div class=\"title f_48 wow fadeInUp animated\"><strong>Application<\/strong><\/div>\n<div class=\"content wow fadeInUp animated\">\n<p>Mainly applied in tension and compression testing instruments and automatic equipments fields, such as small range of force testing instruments, hopper scales, lifting hook scales, insertion force test instruments, and etc.<\/p>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<div class=\"p1 f_24\"><strong>Feature<\/strong><\/div>\n<div class=\"p2 f_20\">\n<ul>\n<li>X-S08 adopts high-precision resistance strain principle.<\/li>\n<li>Supports force measurement in the range of 0-30ton.<\/li>\n<li>Oil, water, corrosion resistance.<\/li>\n<li>Wheel-shape, beautiful appearance.<\/li>\n<li>High dynamic response frequency.<\/li>\n<\/ul>\n<\/div>\n","protected":false},"featured_media":282569,"template":"","meta":[],"product_brand":[2229],"product_cat":[342],"product_tag":[2267,2278],"class_list":{"0":"post-282552","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-xjcsensor-en","7":"product_cat-tension-compression-load-cells","8":"product_tag-load-cell-2-en","9":"product_tag-tension-compression-2-en","11":"first","12":"instock","13":"taxable","14":"shipping-taxable","15":"product-type-simple"},"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/ksensors.co.kr\/en\/wp-json\/wp\/v2\/product\/282552","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ksensors.co.kr\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/ksensors.co.kr\/en\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":0,"href":"https:\/\/ksensors.co.kr\/en\/wp-json\/wp\/v2\/product\/282552\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ksensors.co.kr\/en\/wp-json\/wp\/v2\/media\/282569"}],"wp:attachment":[{"href":"https:\/\/ksensors.co.kr\/en\/wp-json\/wp\/v2\/media?parent=282552"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/ksensors.co.kr\/en\/wp-json\/wp\/v2\/product_brand?post=282552"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/ksensors.co.kr\/en\/wp-json\/wp\/v2\/product_cat?post=282552"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/ksensors.co.kr\/en\/wp-json\/wp\/v2\/product_tag?post=282552"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}