{"id":23953,"date":"2025-07-30T15:14:38","date_gmt":"2025-07-30T06:14:38","guid":{"rendered":"https:\/\/ksensors.co.kr\/product\/hualanhai-ds110e-ba-%ec%bb%ac%eb%9f%bc%ed%98%95-%eb%a1%9c%eb%93%9c%ec%85%80\/"},"modified":"2025-10-14T09:59:52","modified_gmt":"2025-10-14T00:59:52","slug":"hualanhai-ds110e-ba-%ec%bb%ac%eb%9f%bc%ed%98%95-%eb%a1%9c%eb%93%9c%ec%85%80","status":"publish","type":"product","link":"https:\/\/ksensors.co.kr\/en\/product\/hualanhai-ds110e-ba-%ec%bb%ac%eb%9f%bc%ed%98%95-%eb%a1%9c%eb%93%9c%ec%85%80\/","title":{"rendered":"Hualanhai \/ DS110E-BA \/ Column load cell"},"content":{"rendered":"<p>Model: DS110E-BA<\/p>\n<p>Use: Electronic platform scales, electronic truck scales, intelligent IoT (Internet of Things) systems, and industrial equipment load (force) measurement systems<\/p>\n<p>Structural diagram<\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter size-full wp-image-23949\" src=\"https:\/\/ksensors.co.kr\/wp-content\/uploads\/2025\/07\/M4BE6XHVa33Q2j5uflKa7yusb3J06vnHdL6SDZrT.jpeg\" alt=\"\" width=\"1201\" height=\"2107\"><\/p>\n<p>parameter<\/p>\n<table class=\"styled-table\" width=\"700\" cellspacing=\"1\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<p>Rated load<\/p>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<p>10t\/20t\/30t\/40t<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">Accuracy class<\/td>\n<td colspan=\"1\" rowspan=\"1\">C2\/C3<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<p>Composition error<\/p>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<p>\u00b10.03 &amp; \u00b10.02% FS<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<p>Rated output<\/p>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<p>1,000,000 counts<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<p>Creep<\/p>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<p>\u00b10.023 &amp; \u00b10.016% FS\/30min<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<p>Temp.effect on span<\/p>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<p>\u00b10.017 &amp; \u00b10.011% FS\/10\u2103<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<p>Temp.effect on zero<\/p>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<p>\u00b10.029 &amp; \u00b10.019% FS\/10\u2103<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<p>Compensated temp.range<\/p>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<p>-10\u2103 ~ +40 \u2103<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<p>Use temp.range<\/p>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<p>-30\u2103 ~ +70 \u2103<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<p>Excitation voltage<\/p>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<p>10VDC ~ 12VDC<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<p>Baud rate<\/p>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<p>9600 bps<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<p>Communication interface<\/p>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<p>RS485\/RS232<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<p>Data refresh rate<\/p>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<p>50 Hz<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<p>Nmax<\/p>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<p>5000<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<p>Number of bus addresses<\/p>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<p>32<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<p>Maximum transmission distance<\/p>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<p>1000 m<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<p>Safe overload<\/p>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<p>150%<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<p>Ultimate overload<\/p>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<p>200%<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<p>IP code<\/p>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<p>IP68<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p>The extended version of the column sensor has a reduced height compared to the 110E, but the additional ram and lower mounting dimensions are maintained. The installation height can reach up to 158. <\/p>\n","protected":false},"featured_media":23946,"template":"","meta":[],"product_brand":[512],"product_cat":[341],"product_tag":[344,579],"class_list":{"0":"post-23953","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-hualanhai-2","7":"product_cat-cylindrical-column-load-cell","8":"product_tag-load-cell","9":"product_tag---en","11":"first","12":"instock","13":"taxable","14":"shipping-taxable","15":"product-type-simple"},"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/ksensors.co.kr\/en\/wp-json\/wp\/v2\/product\/23953","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ksensors.co.kr\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/ksensors.co.kr\/en\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":0,"href":"https:\/\/ksensors.co.kr\/en\/wp-json\/wp\/v2\/product\/23953\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ksensors.co.kr\/en\/wp-json\/wp\/v2\/media\/23946"}],"wp:attachment":[{"href":"https:\/\/ksensors.co.kr\/en\/wp-json\/wp\/v2\/media?parent=23953"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/ksensors.co.kr\/en\/wp-json\/wp\/v2\/product_brand?post=23953"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/ksensors.co.kr\/en\/wp-json\/wp\/v2\/product_cat?post=23953"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/ksensors.co.kr\/en\/wp-json\/wp\/v2\/product_tag?post=23953"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}