Zemic / L6G Aluminium-alloy IP65 Single Point Load Cell



Share it:

L6G Zemic Load Cell Aluminium-alloy IP65 Single Point Load Cell

Product Description

图片1

Short Description:

◎Aluminium-alloy IP65 single point load cell;

◎Colourless anodized;

◎Suitable for single and double load cells structured platform scales;

◎Maximum platform size: 600 x 600 mm;

◎A 1000 Ohm type available (R1) but is excluded from OIML;

 

Dimensions in mm:

图片1-

Available models:

Capacity Accuracy Full article description Capacity Accuracy Full article description
50kg C3 L6G-C3-50kg-3G6 250 kg C3/C4 L6G-C3/C4-250kg-3G6
100 kg C3 L6G-C3-100kg-3G6 300kg C3/C4 L6G-C3/C4-300kg-3G6
150kg C3/C4 L6G-C3/C4-150kg-3G6 500kg C3/C4 L6G-C3/C4-500kg-3G6
200kg C3/C4 L6G-C3/C4-200kg-3G6 600kg C3/C4 L6G-C3/C4-600kg-3G6

Specification:

Accuracy class OIML R60 C3 OIML R60 C4
Output sensitivity(= FS) mV/V 2.0 ±0.2
Maximum capacity (Emax) kg 50,100, 150,200, 250,300,500,600 150, 200, 250, 300, 500,600
Maximum number of load cell intervals (nLC) 3000 4000
Ratio of minimum LC verification interval Y = Emax / Vmin 10000 15000
Combined error %FS ± 0.02 ±0.0150
Minimum dead load kg 0
Safe overload of Emax 120%
UItimate overload of Emax 150%
Zero balance %FS ± 2.0
Excitation, recommended voltage V 5~12(DC)
Excitation maximum V 18(DC)
Input resistance Ω 406 ±6
Output resistance Ω 350±3
Insulation resistance ≥ 5000(50VDC)
Compensated temperature -10~+40
Operating temperature -35~+65
Storage temperature -40~+70
Element material Aluminium
Recommended torque on fixation N.m M8:25
Ingress protection (according to EN 60529) IP65

 

Wiring:

◎Shielded, 6 conductor cable;

◎Cable diameter: Φ5.9mm;

◎Cable length: 3m;

◎Shield connected to element;

◎Cable jacket in PVC;