Zemic / B6G Single Point Load Cell Platform Scales Load Cell



Share it:

B6G Single Point Load Cell Platform Scales Load Cell

Product Description

图片1

Short Description:

◎Stainless steel IP66 single point load cell;

◎Suitable for single or double load cell structured platform scales;

◎Recommended platform size: 600 x 600 mm;

Available models:

Capacity Accuracy Full article description
xxkg C3 B6G-C3-xxkg-3B6
xxkg C3 B6G-C3-xxkg-3G6
G:The Insulation resistance between bridge circuit and shielded wire is zeroo

Specification:

Accuracy class C3
Output sensitivity(= FS) mV/V 2.0 ±0.2
Maximum capacity( Emax) kg 50,100, 150, 200, 250, 300, 400, 500, 600, 635
Maximum number of load cell intervals (nLC) 3000
Ratio of minimum LC verification interval Y = Emax / Vmin 10000
Combined error %FS ±0.0230
Minimum dead load of Emax 0
Safe overload of Emax 1.5
Uitimate overload of Emax 3
Zero balance %FS ±1.0%
Excitation, recommended voltage V 5~12(DC)
Excitation maximum V 18(DC)
Input resistance Ω 400 ±20
Output resistance Ω 350±3
Insulation resistance ≥ 5000(50VDC)
Compensated temperature -10~+40
Operating temperature -35~+65
Storage temperature -40~+70
Element matenial Stainless steel
Ingress protection (according to EN 60529) IP66
Recommended torque on fixation N.m M8:25
ATEX classification (optional) Ⅱ1G Ex ia ⅡC T4 Ⅱ1D Ex iaD 20 T73℃ Ⅱ3G Ex nL ⅡC T4
Note: S1′ output sensitivity is 2.0+0.002mV/V, input resistance is384±4

Dimensions in mm:

图片2

Wiring:

◎Shielded, 6 conductor cable;

◎Cable diameter: Φ6mm;

◎Standard cable length: 3m;

◎ Shield connected to element;