Product description:

DB903A is a double ended shear beam, both ends loaded, center supported via self-aligning ring groove structure, so that the force can be applied properly. This load cell is suitable for a wide range of truck scales, rail scales and process weighing equipment of tank, bin and hopper scale, etc. It is bolted at both ends.. Fully alloy steel construct, hermetically sealed, which ensure high seals performance of waterproof.

Main Features:

• Material: Alloy steel

• Rated Capacities: 10klb~250klb

• IP Rating: IP68

• Suitable for truck scale, heavy duty hopper scale and other electronic weighing devices.

• High precision by NTEP III L 10000, high reliability.

Category: Double shear beam


Share it:

DB903A SERIES DOUBLE-ENDED SHEAR BEAM LOAD CELL

Patameter Units Specifications
Model No. DB903A
Rated capacity (Emax) klb 10 / 20 / 30 / 50 / 75 / 100 / 150 / 250
Accruacy class 1)2) 0.03%
Min. dead load Ib 0
Rated output mV/V 3.0 ± 0.003
Zero balance % of Emax ± 1
Repeatability error % of AL 3) < ± 0.010
Creep; 30 minute % of AL < ± 0.020
Min. dead load output return (DR); 30 min % of AL < ± 0.020
Temp. effect on Min. dead load output % of Emax/℃ < ± 0.0014
Rated output 2) % of AL/℃ < ± 0.0012
Temperature range Compensated ℃(°F) -10 to +40 [+14 to +104]
Operating -40 to +65 [-40 to +149]
Safe storage -40 to +80 [-40 to +176]
Excitation voltage Recommended V AC/DC 5 ~ 15
Maximum 20
Terminal resistance Excitation Ω 766 ± 10
Output 700 ± 3
Insulation resistance @50VDC >5000
Breakdown voltage V AC >500
Seal type / IP rating Hermetically welded / IP68
Load limit Safe % of Emax 140
Ultimate 200
Material Spring element Alloy steel nickel plated
Cable Φ6; 4-wire; PVC
Cable length m 10K -30klb 50-250klb
12.0 16.0
Weight; approx Ib 10K-20K 30K-75K 100K 150K 250K
7 18 28 34 90
Fatigue life cycles @Emax >1,000,000
Deflection at Emax; approx mm <1.0
Barometric pressure effect on Zero Output Vmin/kPa <1.0
Notes:
1) Error due to the combined effect of non-linearity and hysteresis
2) The sum of errors due to Temperature Effect on Output comply with the requirements of OIML R60 and NIST HB44
3) AL = Applied Load