RJ-6550 Platform scale Load Cell
Technical parameters
| Measuring range | Kg | 50/100/150/200/250/350/500 |
| Sensitivity | mV/V | 2.0±0.2 |
| Accuracy | ±0.02 | |
| Creep | %FS | ±0.02 |
| Input impedance | Ω | 406±20 |
| Output impedance | Ω | 350±5 |
| Insulation resistance | M Ω | ≥5000 (100VDC) |
| Zero balance | %FS | ±1 |
| Temperature effect on sensitivity | %FS/10℃ | ±0.02 |
| Temperature effect on zero | %FS/10℃ | ±0.02 |
| Compensation temperature range | ℃ | -10~+60 |
| Operating temperature range | ℃ | -20~+80 |
| Recommended excitation voltage | V | 5~12 |
| Allowable excitation voltage | V | 18 |
| Safe overload | %FS | 120 |
| Ultimate overload | %FS | 150 |
| Protection level | IP65 | |
| Cable specification | mm | Ф5 |
| Cable length | m | 2 |
| Material | Aluminum Alloy |
Dimensions (mm)


Circuit connection