ME-Systeme / KM26 Column Force Sensor


Measuring range: 100N~10kN

Accuracy: 0.5%FS


Share it:

KM26 Column Force Sensor

Technical

Mechanical Characteristics
Calibration method Pressure
Material Stainless steel
Dimensions mm x mm Ø26 x 11
Fastening method mm Kalotte Ø8, Radius 40
Range N 100,200,500,1k,2k,5k,10k
Safe overload %FS 150
Breaking overload %FS 300
Deflection @ FS mm 0,08
Electrical Characteristics
Sensitivity mV/V @ FS 1
Zero signal mV/V 0,05
Excitation voltage—MAX V 10
Input resistance Ohm 390 ±40
Output resistance Ohm 350
Insulation resistance Ohm >2×109
Cable length m 3
Accuracy Data
Overall accuracy % 0.5
Non-linearity %FS 0,1
Hysteresis %FS 0,05
Zero temperature drift %FS/K 0,02
Sensitivity temperature drift %RD/K 0,02
Creep within 30 minutes %FS 0,1
Temperature
Operating temperature range °C -10 … +70
Service temperature range °C -10 … +85
Protection class IP67

Dimensions

KM26