Interface / TS18 Static torque Sensor


Measurement range: 5~5k Nm

Accuracy: ±0.2%FS


Share it:

TS18 Static torque Sensor

Technical parameters

Category Parameter Value / Unit
Accuracy Class ( MAX ERROR )
Non-linearity ± 0.02 %FS
Combined Error ± 0.2 %FS
Temperature
Compensated Temp. Range -5 to +45 °C
Operating Temp. Range -15 to +55 °C
Zero Temp. Drift (Max) ± 0.02 %RO/°C
Sensitivity Temp. Drift (Max) ± 0.01 %RO/°C
Electrical Characteristics
Sensitivity 1 mV/V
Excitation Voltage (Max) 12 VDC
Output Resistance 350 Ohm
Electrical Connection 6-pin Connector 
Mechanical Characteristics
Safe Overload 150 %CAP
Angular Deflection at Rated Torque < 0.2°
Cyclic Rated Load ± 70 peak

Dimensions

TS18

TS18