Double-Ended Load Cell 643B

케이센서스 스마트스토어

State-of-the-art technologies introduced and upgraded for the more efficient and stable manufacturing of the product. It functions perfectly in the application scenario(s) of Force Sensors & Load Cells. We can provide you with the highest quality products within your budget. Santwell has been dedicated to the design, R&D, manufacturing, and updates of Load cells, Subminiature force transducers, miniature load cells, Intelligent load cells. We fully hope that we can satisfy customers from different fields, countries, and regions by offering them high-quality products and professional service. If you have any questions or problems, please contact us at any time through the contact information listed on our website.
| Model Number: | QS-YBF | Type: | Load Cell |
| Place of Origin: | Zhejiang, China | Brand Name: | Santwell |
| Usage: | truck scale | Theory: | resistan |
| Output: | Resistance strain | Description: | Double ended shear beam load cell |
| Rated Load: | 10/20/30 T | Sensitivity: | 2.0000±0.002mv/v |
| Total Error: | ±0.02%F.S | Creep(30 minutes): | ±0.02%F.S |
| Recommended Excitation Voltage: | 5V-18V(AC or DC) | Maximum Excitation Voltage: | 24V(AC or DC) |
| Zero Balance: | ±1%F.S | Insulation Impedance: | ≥5000MΩ |
| Safe Overload: | ±150%F.S | UItimate Overload: | ±200%F.S |
Capacity: 5-50t
Steel ball loading, strong restoration ability
Easy complete installation, high weighing accuracy
OIML C3 certificate
Alloy Steel, stainless steel
Used for measuring and testing the bearing force.
| Model Number: | QS-J | Type: | Load Cell |
| Place of Origin: | Zhejiang, China | Brand Name: | santwell |
| Usage: | truck scale | Theory: | resistan |
| Output: | Resistance strain | Description: | Double ended shear beam load cell |
| Rated Load: | 10t-30t | Sensitivity: | 2.0000±0.002mv/v |
| Total Error: | ±0.02%F.S | Creep(30 minutes): | ±0.02%F.S |
| Recommended Excitation Voltage: | 5V~18V(AC or DC) | Maximum Excitation Voltage: | 24V(AC or DC) |
| Zero Balance: | ±1%F.S | Insulation Impedance: | ≥5000MΩ |
| Safe Overload: | 150%F.S | UItimate Overload: | 200%F.S |
In the fierce market competition, Ningbo Santwell Import & Export Co., Ltd has grown continuously. We invest in R&D to find better solutions in the Force Sensors & Load Cells industry. We offer buyer Warehouse Measurement 75 Klb 24 V 2Cr14Ni Double Ended shear beam load cell QS-V that they need at prices that fit their pocket. Relying on our excellent products and sensible marketing strategy,Ningbo Santwell Import & Export Co., Ltd hold a firm belief that we will take a large market share in the future and benefit our stakeholders as well.
| Model Number: | QS-V | Place of Origin: | Zhejiang, China |
| Brand Name: | Santwell | Usage: | PRESSURE SENSOR |
| Theory: | Resistance Sensor | Output: | Analog SENSOR |
| Description: | double ended shear beam load cell | Rated Load: | 75klb |
| Sensitivity: | 2.0000 mv/v | Total Error: | ±0.04%F.S |
| Creep(30 minutes): | ±0.02%F.S | Recommended Excitation Voltage: | 5V-18V(AC or DC) |
| Maximum Excitation Voltage: | 24V(AC or DC) | Zero Balance: | ±1%F.S |
| Insulation Impedance: | ≥5000MΩ | Safe Overload: | ±150%F.S |
| UItimate Overload: | ±200%F.S | Application: | Warehouse Measurement |
KWT1B150 is a kind of normal structure weighing sensor, the deign of its tructure makes this weighing sensor easy to install and integrate.
Ningbo Santwell Import & Export Co., Ltd has been manufacturing, exporting and supplying excellent quality Double Ended shear beam load cell weight sensor 10 ton load cell 20 Ton To 120 Ton QS-YBJ. Double Ended shear beam load cell weight sensor 10 ton load cell 20 Ton To 120 Ton QSF can help companies stand out in a fiercely competitive environment and become the industry leader in one fell swoop. So, shake hands with us, expand your business, and increase your clientele.
| Model Number: | QS-YBJ | Place of Origin: | Zhejiang, China |
| Brand Name: | Santwell | Usage: | PRESSURE SENSOR |
| Theory: | Resistance Sensor | Output: | Analog SENSOR |
| Description: | double ended beam load cell | Rated Load: | 20/30/40/50/60/80/120 |
| Sensitivity: | 2.0000±0.002mv/v | Total Error: | ±0.02%F.S |
| Creep(30 minutes): | ±0.02%F.S | Recommended Excitation Voltage: | 5V-18V(AC or DC) |
| Maximum Excitation Voltage: | 24V(AC or DC) | Zero Balance: | ±1%F.S |
| Insulation Impedance: | ≥5000MΩ | Safe Overload: | ±150%F.S |
| UItimate Overload: | ±200%F.S | Application: | In the metallurgical industry metering equipment |
Fixed at both ends, stressed center, low center of gravity, easy to install; High precision, good sealing performance. Suitable for dry-mixed mortar storage tank weighing system.
Ningbo Santwell Import & Export Co., Ltd has a number of elite teams in management, design, R&D, and production. Our product can be tailored to suit you perfectly. Under the leadership of our company’s board of directors, Ningbo Santwell Import & Export Co., Ltd have constantly upgraded our technologies and introduced high-end machines to continuously drive the market trend and improve product quality so as to satisfy every customer. Our aim is to become one of the most trustworthy enterprises in the market.
| Model Number: | QS-KX | Type: | Load Cell |
| Place of Origin: | Zhejiang, China | Brand Name: | santwell |
| Usage: | truck scale | Theory: | resistan |
| Output: | Resistance strain | Description: | Double ended shear beam load cell |
| Rated Load: | 10t-30t | Sensitivity: | 2.0000±0.002mv/v |
| Total Error: | ±0.02%F.S | Creep(30 minutes): | ±0.02%F.S |
| Recommended Excitation Voltage: | 5V~18V(AC or DC) | Maximum Excitation Voltage: | 24V(AC or DC) |
| Zero Balance: | ±1%F.S | Insulation Impedance: | ≥5000MΩ |
| Safe Overload: | 150%F.S | UItimate Overload: | 200%F.S |
Reasonable structure, easy to use and install.It is suitable for the measurement of vehicle-specific scales, crane scales, vehicle wheels and axial forces.
| Model Number: | QS-TL | Type: | Load Cell |
| Place of Origin: | Zhejiang, China | Brand Name: | Santwell |
| Usage: | Truck scale, railway scale, blending scale | Theory: | resistan |
| Output: | Resistance strain | Description: | double ended shear beam |
| Rated Load: | 10t 20t 30t 40t | Sensitivity: | 2.0000±0.002mv/v |
| Total Error: | ±0.02%F.S | Creep(30 minutes): | ±0.02%F.S |
| Recommended Excitation Voltage: | 5V-18V(AC or DC) | Maximum Excitation Voltage: | 24V(AC or DC) |
| Zero Balance: | ±1%F.S | Insulation Impedance: | ≥5000MΩ |
| Safe Overload: | ±150%F.S | UItimate Overload: | ±200%F.S |
After years of painstaking research, Ningbo Santwell Import & Export Co., Ltd’s technicians have successfully developed QS-YBC 10T 20T 30T Digital Weighing Sensor Truck Scale Compression 30T Digital Load Cell. The team uses the most advanced production equipment and independent research and development technology to minimize QS-YBC 10T 20T 30T Digital Weighing Sensor Truck Scale Compression 30T Digital Load Cell development cycle and ensure the high quality and strong reliability of the product. Santwell is a solution for all your buying needs. We can offer you the prices that you need and quality that is good for you.
| Model Number: | QS-TL | Type: | Load Cell |
| Place of Origin: | Zhejiang, China | Brand Name: | Santwell |
| Usage: | Truck scale, railway scale, blending scale | Theory: | resistan |
| Output: | Resistance strain | Description: | double ended shear beam |
| Rated Load: | 10t 20t 30t 40t | Sensitivity: | 2.0000±0.002mv/v |
| Total Error: | ±0.02%F.S | Creep(30 minutes): | ±0.02%F.S |
| Recommended Excitation Voltage: | 5V-18V(AC or DC) | Maximum Excitation Voltage: | 24V(AC or DC) |
| Zero Balance: | ±1%F.S | Insulation Impedance: | ≥5000MΩ |
| Safe Overload: | ±150%F.S | UItimate Overload: | ±200%F.S |
WhatsApp us