HiWEIGH / M28i M28d shear beam Load Cell


Capacity up to 10000Kg | 20klb M28i with OIML approval (till 2500kg) M28d with OIML/NTEP approval


Share it:

M28i M28d shear beam Load Cell

Features

  • M28i-CE (till 2500kg)
  • M28D-OIML/NTEP
  • Capacity up to 10000kg
  • Stainless steel material
  • Optional rubber pads for leveling feet
  • Default cable length is 5m-M28i
  • Default cable length is 6m-M28D
    (Optional customized longer cable)
  • Interchangeable with below models: HMB* BLC/ELC, Mettler Toledo* SLB515, Tedea-Huntleigh* 3410/3411, Revere*ACB, Celtron*SQB-HSS, Zemic* BM8D, Flintec* SB14/SLB

 

Models

Part No. 120152 120153 120154 120155 120156
M28i 500kg 1000kg 1500kg 2000kg 2500kg
Part No. 120157 120158 120159 120160 120161 120162 120163 120164
M28D 500kg 1000kg 1500kg 2000kg 2500kg 5000kg 7500kg 10000kg
Part No. 120165 120166 120167 120168 120169 120170 120171 120172
M28D 1klb 2klb 2.5klb 5klb 7.5klb 10klb 15klb 20klb
Class C3/N5
IP IP68
Item Specification
Capacity 500 – 10,000 kg1 klb – 20 klb
Sensitivity 2.0 ± 0.002 mV/V3.0 ± 0.008 mV/V
Accuracy C3 | C4 | C5
Non-Linearity ±0.02% Emax
Zero Balance ±1% Emax
Repeatability 0.02% Emax
Combined Error ≤ 0.02% FS
Temperature Effect on Zero (TE Zero) 0.018% FS / 10℃
Temperature Effect on Span (TE Span) 0.014% FS / 10℃
Input Resistance 350 ± 3.5 Ω
Output Resistance 350 ± 3.5 Ω
Insulation Resistance ≥ 5000 MΩ
Operating Temperature Range -35 ~ 65 ℃
Overload Limitation 150% F.S.
Recommended Excitation 5 – 12 VDC
Protection IP68