FEATURES
- Aluminum alloy,surface anodized and anticorrosion;
- Built-in digital module, digital signal output, RS485 or RS232; Max platform size: 400×500mm;
- Factory calibration, no calibration required;
- Modify the acceleration of gravity and can be used in other places without calibration;
- To change division value, after that, the corresponding weight can be output, no need for field calibration; The sensor has only one zero-setting command and a weight read command are immediately accessed; Mainly used in smart shelves, smart gravity cabinets, garbage recycling and others.
PARAMETER
| Rated Load | 60,100,200,350,500(kg) | ||
|
Division Value |
≤50kg,1g | A/D Resolution | 300000 |
| 60~100kg,2g |
Weight data output rate |
RS485:3ms | |
| 150~200kg,5g | RS232:20ms | ||
| 300~500kg,10g |
Operating Temp.Range |
RS485:-20~+70℃ | |
| Detectability * | Default 1 | RS232:-10~+70℃ | |
| Comprehensive Error | 0.005%F.S | Excitation,Recommende | 5~12VDC |
| Temp. Effect on Output | 0.002%F.S/℃ | Safe Overload | 150% |
| Temp. Effect on Zero | 0.002%F.S/℃ | Ultimate Overload | 200% |
| Creep | 0.018%F.S/30min | Cable | 4-Wire Shielded Cable |
| Output | RS485 or RS232 | Cable length | Φ5mm×2m |
|
Baud rate |
RS485:115200 | Ingress Protection | IP65 |
| RS232:19200 |
Communication Protocol |
RS485:MODBUS RTU/ Custom protocol | |
| A/D Sampling Rate | 1200 times/sec | RS232: Custom protocol | |
WIRING
| Rs232 | RS485 | Color | Explain |
| +V | +V | Red | 5~12VDC |
| GND | GND | Black | 0V |
| RD | A | Green | Connect external device TXD or A |
| TD | B | White | Connect external device RXD or B |