GML691A Micro load cell
| Range(kg) | 10 | 30 | 50 |
| H | 1.5 | 2.0 | 2.5 |
| Rated output(mV/V) | 1.0±0.2 | 0.7±0.1 | 1.1±0.15 |

SPECIFICATION
| Rated Load(single) | 10,30,50(kg) | ||
| Comprehensive Error | ±0.05%F.S | Excitation,Recommended | 5VDC |
| Rated Output | See table above | Operating Voltage | 3~10VDC |
| Zero Balance | ±0.5mV/V | Safe Overload | 120%F.S |
| Linearity Error | ±0.05%F.S | Limit Overload | 150%F.S |
| Repeatability Error | ±0.05%F.S | Insulation Resistance | ≥2000MΩ(100VDC) |
| Hysteresis Error | ±0.05%F.S | Cable | Three Color PVC Wires |
| Creep | ±0.05%F.S/3min | Cable,Length | φ0.8×420mm |
| Input Resistance | 500/1000±10Ω | Ingress Protection | IP65 |
| Output Resistance | 500/1000±10Ω | Four-angle Error | 1.0%F.S |
| Temp.Effect on Output | ±0.1%F.S/10℃ |
Wiring Definitions |
Common : Red |
| Temp.Effect on Zero | ±0.1%F.S/10℃ | Signal + : Black | |
| Operation Temp. Range | – 10~+40℃ | Signal – : White | |