Models
DYN-208
Features
-
Capable of measuring non-rotating and rotating torque
-
Strong anti-interference, high precision, and excellent stability
-
Digitalized output signal, compact, and lightweight
-
Easy to install, enabling contactless transmission of power and signals
-
Signal transmission is independent of rotation, rotation speed, and direction
-
Continuous forward and reverse torque signal transmission without repetitive zero adjustments
-
No wear parts such as current collectors, enabling high-speed, long-term operation
-
No bearings between the housing and the rotating plate, making it suitable for long-term, high-speed operation and capable of transmitting non-rotating, rotating, static, and dynamic torque
Dimensions

Specifications
| Specification | Unit | Value |
|---|---|---|
| Rated Torque | N·m | 0–1000 |
| Speed Range | rpm | 8000 |
| Speed Signal | pulses/rev | 60 (>10000N·m: 180) |
| Power Supply | V DC | 24 |
| Operating Voltage | V | 5–15 |
| Zero Output | %F.S. | 0.2 |
| Non-linearity | %F.S. | 0.2 |
| Hysteresis | %F.S. | 0.2 |
| Repeatability | %F.S. | 0.2 |
| Creep (30 minutes) | %F.S. | 0.03 |
| Temp. Drift (Sensitivity) | %F.S./10℃ | 0.01 |
| Temp. Drift (Zero) | %F.S./10℃ | 0.01 |
| Response Frequency | kHz | 10 |
| Material | — | Alloy Steel |
| Annual Stability | /year | 0.3% |
| Impedance | Ω | 750 |
| Insulation Resistance | MΩ/100V DC | ≥5000 |
| Operating Temperature Range | ℃ | -20 to 80 |
| Relative Humidity | %RH | 0–90 |
| Safe Overload | — | 120% |
| Ultimate Overload | — | 150% |
| Cable Specification | — | Φ5×3 |
| Cable Max Tension | kg | 10 |