DAYSENSOR / DYLF-106 / Pressure Load Cell


This sensor is a high-stability weight measurement sensor with a low structural height and high precision, and is widely used in the fields of industrial scales and automation equipment.


Share it:

Models

DYLF-106

Features

  • High stability

  • Low structural height

  • High overall precision

  • Signal is interference-resistant and stable

  • Nickel plating is used on high-grade alloy steel

  • Widely used in weighing equipment such as electronic belt scales, packaging scales, and filling scales, as well as in automated equipment and testing applications

Dimensions

 

Capacity(mm) A B C D H H1 H2 H3 E F N M G K L P
0.5~1T 53 26 48 80 39 24 10 11 63 42 4 6 6 9 8 45º
2~15T 80 40 76 118 58 40 12 15 95 64 6 8 9 14 12 30º
20~50T 102 60 96 146 74 48 20 20 121 81 8 10 11 17 13 22.5º

Specifications

Item Unit Specification
Rated Capacity T 50
Output Sensitivity mV/V 2.0 ±0.05
Zero Output %F.S. ±1
Non-linearity %F.S. 0.2
Hysteresis %F.S. 0.2
Repeatability %F.S. 0.2
Creep (30 min) %F.S. 0.2
Temp. Effect on Sensitivity %F.S./10℃ 0.03
Temp. Effect on Zero %F.S./10℃ 0.03
Frequency Response Hz 10k
Material Alloy Steel
Impedance Ω 700
Insulation Resistance MΩ/50V DC ≥5000
Excitation Voltage V 5–15
Operating Temperature -20 to 80
Safe Overload %R.C. 150
Ultimate Overload %R.C. 200
Cable Specification m Φ5×3m
Cable Tension Limit kg 10
TEDS Optional