Models
DYHW-116
Features
-
High stability
-
Can be installed in confined spaces
-
Non-standard customization available.
-
It is highly resistant to signal interference, ensuring stable output.
-
Made from high-grade stainless steel.
-
Widely used in automation applications such as load measurement in 3C digital product manufacturing and inspection processes, auxiliary equipment, and robotic arms.
Dimensions

| Capacity(mm) | ΦA | ΦC | ΦD | H | E | M | H1 | SR |
| 3~200kg | 20 | 2.5 | 15.5 | 12 | 10 | M3 | 4 | 2 |
| 300~500kg | 26 | 5 | 18.5 | 15 | 11.5 | M4 | 5 | 6 |
| 1~5t | 37.7 | 10.8 | 31 | 15.5 | 14 | M2.5 | 4 | 50 |
Specifications
| Item | Unit | Specification |
|---|---|---|
| Rated Capacity | T | 0–10 |
| Output Sensitivity | mV/V | 1.0–2.0 |
| Zero Balance | %F.S. | ±1 |
| Non-linearity | %F.S. | 0.3 |
| Hysteresis | %F.S. | 0.3 |
| Repeatability | %F.S. | 0.3 |
| Creep (30 min) | %F.S. | 0.1 |
| Temperature Effect on Sensitivity | %F.S./10℃ | 0.3 |
| Temperature Effect on Zero | %F.S./10℃ | 0.3 |
| Frequency Response | Hz | 10k |
| Material | — | Stainless Steel |
| Impedance | Ω | 700/1000 |
| Insulation Resistance | MΩ/100V DC | ≥5000 |
| Excitation Voltage | V | 5–10 |
| Operating Temperature Range | ℃ | -20 to 80 |
| Safe Overload | %R.C. | 150 |
| Ultimate Overload | %R.C. | 200 |
| Cable Specification | m | Φ3×2m (10T: Φ5×2m) |
| Cable Maximum Tension | kg | 10 |
| TEDS | — | Optional |