Interface / WMCRE column tension and compression


Measuring range: 22.5N 2.25kN

Accuracy: ±0.15% 


Share it:

WMCRE column tension and compression

Technical parameters

Category Parameter 15K, 20K, 30K, 50Klbf (90, 130, 220kN) 100K lbf 200K lbf
Accuracy Class ( MAX ERROR )
Non-linearity Error — %FS 0.10 0.15 0.20
Hysteresis — %FS 0.10 0.15 0.20
Repeatability — %RO 0.05 0.05 0.05
Creep (20 min) — % 0.05 0.05 0.05
Temperature
Compensated Temp. Range (°C) -10 to 45 -10 to 45 -10 to 45
Operating Temp. Range (°C) -54 to 121 -54 to 121 -54 to 121
Temp. Effect on Sensitivity — %/°C 0.0072 0.009 0.009
Temp. Effect on Zero — %RO/°C 0.0045 0.009 0.009
Electrical
Rated Output — mV/V 2.0 2.0 2.0
Zero Balance — %RO 1.0 1.0 1.0
Output Resistance — Ohm 350 ± 3.5 350 ± 3.5 350 ± 3.5
Excitation Voltage 15 VDC 15 VDC 15 VDC
Insulation Resistance — Megohm > 5000 > 5000 > 5000
Mechanical
Calibration Mode Tension & Compression Tension & Compression Tension & Compression
Safe Overload — %CAP 150 150 150
Deflection @ RO 0.004 in (0.10 mm) 0.004 in 0.004 in
Weight — kg 1.8 6.3 15.5


Dimensions

WMCRE column tension and compression

WMCRE column tension and compression