3KA225 Series Three-Component Sensor
Technical Specifications
| Parameter type | Parameter Indicators |
| range | Fx :150kN – 250kN , Fy: 150kN – 250kN , Fz : 400kN – 1000kN |
| Rated force Fx | ±150kN, ±200kN, ±250kN |
| Rated force Fy | ±150kN, ±200kN, ±250kN |
| Rated force Fz | ±400kN, ±800kN, ±1000kN |
| Sensitivity Fx/Fy | 1.5 ~ 2.0mV/V |
| Sensitivity Fz | 0.6 ~ 1.2mV/V |
| Zero-point output | ≤3%FS |
| Safe overload Fx/Fy/Fz | 150%FS |
| Ultimate overload Fx/Fy/Fz | 200%FS |
| Shell material | alloy steel |
| accuracy | Parameter Indicators |
| Linearity Fx/Fy/Fz | ≤ 0.3%FS |
| Repeatability Fx/Fy/Fz | ≤ 0.1%FS |
| Crosstalk Fx . Fy . Fz | ≤ 2.5%FS |
| Electrical parameters | Parameter Indicators |
| Excitation voltage | 5~10VDC |
| Input impedance | 120 ± 35Ω |
| Output impedance | 1400 ± 30Ω |
| Interface method | Parameter Indicators |
| Output interface | Aircraft plug interface (default) |
| Cable length | 5m (default) |
| Temperature environment | Parameter Indicators |
| Operating temperature | -20 ~ 60 ℃ |
| Storage temperature | -20 ~ 85 ℃ |
| Protection level | IP65 |
| other | Parameter Indicators |
| size | Φ225 * H150mm, see dimension drawing for details. |
| custom made | Explosion-proof is optional; measuring range can be customized (xy):z=1:3 |
Dimensions