Zemic / B6E3 H6E3 Stainless/ Alloy Steel IP67 Single Point Load Cell



Share it:

B6E3 H6E3 Stainless/ Alloy Steel IP67 Single Point Load Cell

Product Description

图片1

Short Description:

◎Stainless/ alloy steel IP67 single point load cell;

◎ Suitable for the pricing scales, bench scales, belt scales etc;

◎Maximum platform size: 400*400mm;

Available models:

Capacity Accuracy Full article description
xxkg C3 B6E3/H6E3-C3-xxkg-3B
xxkg C3 B6E3/H6E3-C3-xxkg-3B-S1
xxkg C3 B6E3/H6E3-C3-xxkg-3G
xxkg C3 B6E3/H6E3-C3-xxkg-3G-S1
G:The Insulation resistance between bridge circuit and shielded wire is zero

Specification:

Maximum capacity ( Emax) kg 20/30/50/75/100/150/200/250/300
Accuracy dlass C3
Maximum number of verification intervals 3000
Maximum number of load cell intervals (nLC) N.max Emax/10000
Combined error %FS ±0.020
Creep %FS/30min ±0.016
Temperature effect on sensitivity %FS/10℃ ±0.011
Temperature effect on zero %FS/10℃ ±0.015
Output sensitivity(= FS) mV/V 2.0+0.2
Input resistance Ω 400±20
Output resistance Ω 351±3.5
Insulation resistance ≥ 5000(50VDC)
Zero balance %FS ±1.5
Compensated temperature -10~+40
Operating temperature -35~+65
Excitation, recommended voltage V 5~12(DC)
Excitation maximum V 18(DC)
Safe overload %FS 150
Ultimate overload %FS 300
Corner correction 0.02%load value/100mm
ATEX class( optional) Ⅱ1G Ex ia ⅡC T4 Ⅱ1D Ex iaD 20 T73℃ Ⅱ3G Ex nL ⅡC T4
Note: “S1” output sensitivity is 2.0± 0.002mV/V,input resistance is 384 ±4

Dimensions in mm:

图片2图片3

Wiring:

◎Adopt shielded, 4 conductor cable: Φ5mm;

◎Standard cable length: 3m;