LC3517 200kg Aluminum Weighing Scale Load Cell Aluminum Load Cell

Recommended Platform size: 350×400(mm)
Dimensions:

Technical Parameter:
케이센서스 스마트스토어

Recommended Platform size: 350×400(mm)
Dimensions:

Technical Parameter:
| Rated Load: | 20/30/50/60/100/150/200/250/300kg | ||
| Comprehensive Error: | 0.02%F.S | Insulation Resistance: | ≥5000MΩ(100VDC) |
| Rated Output: | 2±0.1mV/V | Excitation Voltage: | 9VDC~12VDC |
| Non-Linearity: | 0.02%F.S | Compensated Temp. Range: | -10℃~+40℃ |
| Hysteresis: | 0.02%F.S | Use Temp. Range: | -20℃~+60℃ |
| Repeatability: | 0.02%F.S | Temp. Effect On Zero: | 0.03%F.S/10℃ |
| Creep: | & 0.02%F.S/10min | Temp. Effect On Span: | 0.02%F.S/10℃ |
| Zero Balance: | ±1%F.S | Safe Overload: | 120% |
| Input Resistance: | 405±10Ω | Ultimate Overload: | 150% |
| Output Resistance: | 350±3Ω | Defense Class: | IP65 |
| Product name | LC3517 China 200kg Aluminum Weighing Scale Load Cell Aluminum Load Cell |
| Brand | SAINTBOND |
| Market | All over the world |
| Features | High precision and stable performance |
| Advantage | 0EM/ODM |
| Sample Lead Time | 5~ 40Days |
| Sample price | The price is different according to product capacity |
| Custom Design | Welcome |
| Form of sale | Factory supply |
LCT Single Point Load Cells have been designed such that their excellent mechanical and measurement properties can be optimally used in a wide range of applications. A Single Point Load Cells is also called Platform Load Cell.
Advantages of LCT Single Point Load Cells / Platform Load Cells:
Quick to install thanks to off-center load compensation at the factory (per OIML R60),and only one unit is sufficient to build up a scale.
Model LAK-E load cells are designed to this “single point”type and manufactured from high quality aluminum alloy of aviation standard. LAK-E load cells can be used to measure loads range from 0.3kg to 3kg with the measuring accuracy of 0.03% R.O.( R.O.=Rated Output)
LAK-E load cells are mainly used for electronic balances,counting scales,jewellery scales and retail scales.
LCT Single Point Load Cells have been designed such that their excellent mechanical and measurement properties can be optimally used in a wide range of applications. A Single Point Load Cells is also called Platform Load Cell.
Advantages of LCT Single Point Load Cells / Platform Load Cells:
Quick to install thanks to off-center load compensation at the factory (per OIML R60),and only one unit is sufficient to build up a scale.
Model LAB-I3 load cells are designed to this “single point”type and manufactured from high quality aluminum alloy of aviation standard. LAB-I3 load cells can be used to measure loads range from 20kg to 100kg with the measuring accuracy of 0.02% R.O.( R.O.=Rated Output)
LAB-I3 load cells are mainly used for price computing scales,counting scales,weighing scales,retail scales and bench scale.
LCT Single Point Load Cells have been designed such that their excellent mechanical and measurement properties can be optimally used in a wide range of applications. A Single Point Load Cells is also called Platform Load Cell.
Advantages of LCT Single Point Load Cells / Platform Load Cells:
Quick to install thanks to off-center load compensation at the factory (per OIML R60),and only one unit is sufficient to build up a scale.
Model LAB-B-B load cells are designed to this “single point”type and manufactured from high quality aluminum alloy of aviation standard. LAB-B-B load cells can be used to measure loads range from 3kg to 50kg with the measuring accuracy of 0.03% R.O.( R.O.=Rated Output)
LAB-B-B load cells are mainly used for price computing scales,counting scales,weighing scales,retail scales and bench scale.
LCT Planar beamload cells have been designed such that their excellent mechanical and measurement properties can be optimally used in a wide range of applications. They are designed for those who need to produce equipment with minimal overall height. They are usually implemented in sets of three or four per scale.
Advantages of LCT Planar beam load cells:
Most planar beams are not corner-adjusted. Using 3 or 4 Planar beam load cells is an alternative to a single point load cell configuration with the additional benefit of a practical unlimited platform size.
Model LAA-W7 load cells are designed to this “Planar beam”type and manufactured from high quality aluminum alloy of aviation standard. LAA-W7 load cells can be used to measure loads range from 75kg to 300kg with the measuring accuracy of 0.05% R.O.( R.O.=Rated Output)
LAA-W7 load cells are mainly used for retail scales, medical scales,personal scales,bathroom scales,airport baggage scales,postal scales and any weighing environment where space is a limiting factor.
Description
LCT Single Point Load Cells have been designed such that their excellent mechanical and measurement properties can be optimally used in a wide range of applications. A Single Point Load Cells is also called Platform Load Cell.
Advantages of LCT Single Point Load Cells / Platform Load Cells:
Quick to install thanks to off-center load compensation at the factory (per OIML R60),and only one unit is sufficient to build up a scale.
Model LAB-C6A load cells are designed to this “single point”type and manufactured from high quality aluminum alloy of aviation standard. LAB-C6A load cells can be used to measure loads range from 3kg to 40kg with the measuring accuracy of 0.03% R.O.( R.O.=Rated Output)
LAB-C6A load cells are mainly used for price computing scales,counting scales,weighing scales,retail scales and bench scale.
SC601은 상업용으로 설계된 단일형 로드셀입니다. 구조가 간단하여 고정단과 유동단 사이의 측정이 용이합니다. 또한, SC601은 다양한 용도에 적합한 넓은 측정 범위를 제공하여 매우 다재다능하며, 최대 120kg까지 측정 가능합니다.
This SC601 is a single type load cell designed for commercial applications. Its simple structure allows easy measurement between its fixed end and floating end. The SC601 is also very versatile with a wide measurement range for many different applications and has a maximum on 120kg.
LCT Single Point Load Cells have been designed such that their excellent mechanical and measurement properties can be optimally used in a wide range of applications. A Single Point Load Cells is also called Platform Load Cell.
Advantages of LCT Single Point Load Cells / Platform Load Cells:
Quick to install thanks to off-center load compensation at the factory (per OIML R60),and only one unit is sufficient to build up a scale.
Model LAQ-C load cells are designed to this “single point”type and manufactured from high quality aluminum alloy of aviation standard. LAQ-C load cells can be used to measure loads range from 200kg to 2000kg with the measuring accuracy of 0.02% R.O.( R.O.=Rated Output)
LAQ-C load cells are mainly used for price computing scales,counting scales,weighing scales,retail scales, bench scale, platform scales and packing machinerys.
LCT Single Point Load Cells have been designed such that their excellent mechanical and measurement properties can be optimally used in a wide range of applications. A Single Point Load Cells is also called Platform Load Cell.
Advantages of LCT Single Point Load Cells / Platform Load Cells:
Quick to install thanks to off-center load compensation at the factory (per OIML R60),and only one unit is sufficient to build up a scale.
Model LAB-H-B load cells are designed to this “single point”type and manufactured from high quality aluminum alloy of aviation standard. LAB-H-B load cells can be used to measure loads range from 20kg to 200kg with the measuring accuracy of 0.03% R.O.( R.O.=Rated Output)
LAB-H-B load cells are mainly used for price computing scales,counting scales,weighing scales,retail scales and bench scale.
LCT Single Point Load Cells have been designed such that their excellent mechanical and measurement properties can be optimally used in a wide range of applications. A Single Point Load Cells is also called Platform Load Cell.
Advantages of LCT Single Point Load Cells / Platform Load Cells:
Quick to install thanks to off-center load compensation at the factory (per OIML R60),and only one unit is sufficient to build up a scale.
Model LAC-A load cells are designed to this “single point”type and manufactured from high quality aluminum alloy of aviation standard. LAC-A1 load cells can be used to measure loads range from 1.5kg to 6kg with the measuring accuracy of 0.03% R.O.( R.O.=Rated Output)
LAC-A load cells are mainly used for electronic balances,counting scales,jewellery scales and retail scales.
WhatsApp us