LC3517 200kg Aluminum Weighing Scale Load Cell Aluminum Load Cell

Recommended Platform size: 350×400(mm)
Dimensions:

Technical Parameter:
케이센서스 스마트스토어

Recommended Platform size: 350×400(mm)
Dimensions:

Technical Parameter:
| Rated Load: | 20/30/50/60/100/150/200/250/300kg | ||
| Comprehensive Error: | 0.02%F.S | Insulation Resistance: | ≥5000MΩ(100VDC) |
| Rated Output: | 2±0.1mV/V | Excitation Voltage: | 9VDC~12VDC |
| Non-Linearity: | 0.02%F.S | Compensated Temp. Range: | -10℃~+40℃ |
| Hysteresis: | 0.02%F.S | Use Temp. Range: | -20℃~+60℃ |
| Repeatability: | 0.02%F.S | Temp. Effect On Zero: | 0.03%F.S/10℃ |
| Creep: | & 0.02%F.S/10min | Temp. Effect On Span: | 0.02%F.S/10℃ |
| Zero Balance: | ±1%F.S | Safe Overload: | 120% |
| Input Resistance: | 405±10Ω | Ultimate Overload: | 150% |
| Output Resistance: | 350±3Ω | Defense Class: | IP65 |
| Product name | LC3517 China 200kg Aluminum Weighing Scale Load Cell Aluminum Load Cell |
| Brand | SAINTBOND |
| Market | All over the world |
| Features | High precision and stable performance |
| Advantage | 0EM/ODM |
| Sample Lead Time | 5~ 40Days |
| Sample price | The price is different according to product capacity |
| Custom Design | Welcome |
| Form of sale | Factory supply |
LCT Single Point Load Cells have been designed such that their excellent mechanical and measurement properties can be optimally used in a wide range of applications. A Single Point Load Cells is also called Platform Load Cell.
Advantages of LCT Single Point Load Cells / Platform Load Cells:
Quick to install thanks to off-center load compensation at the factory (per OIML R60),and only one unit is sufficient to build up a scale.
Model LAB-B-B load cells are designed to this “single point”type and manufactured from high quality aluminum alloy of aviation standard. LAB-B-B load cells can be used to measure loads range from 3kg to 50kg with the measuring accuracy of 0.03% R.O.( R.O.=Rated Output)
LAB-B-B load cells are mainly used for price computing scales,counting scales,weighing scales,retail scales and bench scale.
SC601은 상업용으로 설계된 단일형 로드셀입니다. 구조가 간단하여 고정단과 유동단 사이의 측정이 용이합니다. 또한, SC601은 다양한 용도에 적합한 넓은 측정 범위를 제공하여 매우 다재다능하며, 최대 120kg까지 측정 가능합니다.
This SC601 is a single type load cell designed for commercial applications. Its simple structure allows easy measurement between its fixed end and floating end. The SC601 is also very versatile with a wide measurement range for many different applications and has a maximum on 120kg.
LCT Single Point Load Cells have been designed such that their excellent mechanical and measurement properties can be optimally used in a wide range of applications. A Single Point Load Cells is also called Platform Load Cell.
Advantages of LCT Single Point Load Cells / Platform Load Cells:
Quick to install thanks to off-center load compensation at the factory (per OIML R60),and only one unit is sufficient to build up a scale.
Model LAK-H1 load cells are designed to this “single point”type and manufactured from high quality aluminum alloy of aviation standard. LAK-H1 load cells can be used to measure loads range from 0.3kg to 3kg with the measuring accuracy of 0.03% R.O.( R.O.=Rated Output)
LAK-H1 load cells are mainly used for electronic balances,counting scales,jewellery scales and retail scales.
The SC602 is a single-type load cell designed for small applications requiring high capacity. It shares the same structure as the SC601 but is shorter to minimize installation space. Despite its smaller size, it maintains a wide measuring range of up to 100 kg.
This SC602 is a single type load cell designed for compact applications that need high capacity. It follows the same structure of the SC601 but is shorter to minimize its foot print. Despite its smaller size is still maintains the wide measurement range for this load cell type with a maximum of 100kg.
LCT Single Point Load Cells have been designed such that their excellent mechanical and measurement properties can be optimally used in a wide range of applications. A Single Point Load Cells is also called Platform Load Cell.
Advantages of LCT Single Point Load Cells / Platform Load Cells:
Quick to install thanks to off-center load compensation at the factory (per OIML R60),and only one unit is sufficient to build up a scale.
Model LAP-B1-A load cells are designed to this “single point”type and manufactured from high quality aluminum alloy of aviation standard. LAP-B1-A load cells can be used to measure loads range from 3kg to 40kg with the measuring accuracy of 0.03% R.O.( R.O.=Rated Output)
LAP-B1-A load cells are mainly used for price computing scales,counting scales,weighing scales,retail scales and packing machinerys.
LCT Single Point Load Cells have been designed such that their excellent mechanical and measurement properties can be optimally used in a wide range of applications. A Single Point Load Cells is also called Platform Load Cell.
Advantages of LCT Single Point Load Cells / Platform Load Cells:
Quick to install thanks to off-center load compensation at the factory (per OIML R60),and only one unit is sufficient to build up a scale.
Model LAK-E load cells are designed to this “single point”type and manufactured from high quality aluminum alloy of aviation standard. LAK-E load cells can be used to measure loads range from 0.3kg to 3kg with the measuring accuracy of 0.03% R.O.( R.O.=Rated Output)
LAK-E load cells are mainly used for electronic balances,counting scales,jewellery scales and retail scales.
LCT Single Point Load Cells have been designed such that their excellent mechanical and measurement properties can be optimally used in a wide range of applications. A Single Point Load Cells is also called Platform Load Cell.
Advantages of LCT Single Point Load Cells / Platform Load Cells:
Quick to install thanks to off-center load compensation at the factory (per OIML R60),and only one unit is sufficient to build up a scale.
Model LAQ-C load cells are designed to this “single point”type and manufactured from high quality aluminum alloy of aviation standard. LAQ-C load cells can be used to measure loads range from 200kg to 2000kg with the measuring accuracy of 0.02% R.O.( R.O.=Rated Output)
LAQ-C load cells are mainly used for price computing scales,counting scales,weighing scales,retail scales, bench scale, platform scales and packing machinerys.
20,50,100,200,300,400,500kg Or Customized Single Point Weight Sensor FA524 is a customizable model of our brand FIBOS FA5-Series, Single Point Weight Sensor can be used to measure 20kg,50kg,100kg,200kg,300kg,400kg and 500kg or customized capacity, its Zero balance range is ±1.5%F.S. or customized, its Creep(30min) and Non-linearity both ≤0.19%F.S. or can be customized, its Hysteresis and Repeatability both ≤0.2%F.S. or also can be customized.
이 SC601AC는 고용량 어플리케이션용으로 설계된 단일형 로드셀입니다. SC601과 동일한 구조를 따르지만, 최대 200kg의 더 높은 용량을 달성하기 위해 약간 더 큽니다. SC601AC는 양쪽 끝에 삼각형 모양의 구멍 3개가 있는 약간 다른 장착 방식을 가지고 있습니다. 적절한 구멍 크기와 간격은 기계 도면을 참조하십시오.
This SC601AC is a single type load cell designed for high capacity applications. It follows the same structure of the SC601 but is slightly larger in order to achieve higher capacities of up to 200kg. The SC601AC also has a slightly different mounting setup with 3 holes on each end in triangle formation. Please refer to the mechanical drawings for proper hole size and spacing
LCT Single Point Load Cells have been designed such that their excellent mechanical and measurement properties can be optimally used in a wide range of applications. A Single Point Load Cells is also called Platform Load Cell.
Advantages of LCT Single Point Load Cells / Platform Load Cells:
Quick to install thanks to off-center load compensation at the factory (per OIML R60),and only one unit is sufficient to build up a scale.
Model LAC-A2 load cells are designed to this “single point”type and manufactured from high quality aluminum alloy of aviation standard. LAC-A2 load cells can be used to measure loads range from 1.5kg to 6kg with the measuring accuracy of 0.03% R.O.( R.O.=Rated Output)
LAC-A2 load cells are mainly used for electronic balance,counting scales,weighing scales,retail scales,jewellery scales,kitchen scales,coffee machine and packing machine.
LCT Single Point Load Cells have been designed such that their excellent mechanical and measurement properties can be optimally used in a wide range of applications. A Single Point Load Cells is also called Platform Load Cell.
Advantages of LCT Single Point Load Cells / Platform Load Cells:
Quick to install thanks to off-center load compensation at the factory (per OIML R60),and only one unit is sufficient to build up a scale.
Model LAB-C6A load cells are designed to this “single point”type and manufactured from high quality aluminum alloy of aviation standard. LAB-C6A load cells can be used to measure loads range from 3kg to 40kg with the measuring accuracy of 0.03% R.O.( R.O.=Rated Output)
LAB-C6A load cells are mainly used for price computing scales,counting scales,weighing scales,retail scales and bench scale.
WhatsApp us
