LC3531 Platform Load Cell Weight Sensor Miniature Sensors

Dimensions:

Technical Parameter:
케이센서스 스마트스토어

Dimensions:

Technical Parameter:
| Model | LC3531 | Temp.Effect on Output | ±0.02%F.S/10℃ |
| Capacity | 5/15/40kG | Zero Output | ±0.08%F.S |
| Comprehensive Error | 0.03 | Input Resistance | 395±10Ω |
| Output Sensitivity | 2.0±0.2mV/V | Output Resistance | 350±10Ω |
| Non-linearity | ±0.02%F.S | Insulation Resistance | ≥3000MΩ (50V) |
| Repeatability | ±0.02%F.S | Excitation Voltage | ≤10V |
| Hysteresis | ±0.02%F.S | Operation Temp.Range | -10–+40℃ |
| Creep | ±0.03(5min)%F.S | Overload Capacity | 150%F.S |
| Temp.Effect on Zero | ±0.05%F.S/10℃ | Recommended Use | For waterproof scales |
| Product name | LC3531 Platform Load Cell Weight Sensor Miniature Sensors |
| Brand | SAINTBOND |
| Market | All over the world |
| Features | High precision and stable performance |
| Advantage | 0EM/ODM |
| Sample Lead Time | 5~ 40Days |
| Sample price | The price is different according to product capacity |
| Custom Design | Welcome |
| Form of sale | Factory supply |
5,10,20,50,80,100kg Or Customized Single Point Weight Sensor FA537 is a model of our brand FIBOS FA5-Series, Single Point Weight Sensor FA537 can be used to measure weight ranges from 5kg,10kg,20kg,50kg,80kg up to 100kg or could be customized capacity, its Creep(30min) and Repeatability both ≤0.18%F.S. or could be customized, and its Non-linearity and Hysteresis both ≤0.2%F.S. or customized.
LCT Single Point Load Cells have been designed such that their excellent mechanical and measurement properties can be optimally used in a wide range of applications. A Single Point Load Cells is also called Platform Load Cell.
Advantages of LCT Single Point Load Cells / Platform Load Cells:
Quick to install thanks to off-center load compensation at the factory (per OIML R60),and only one unit is sufficient to build up a scale.
Model LAC-A load cells are designed to this “single point”type and manufactured from high quality aluminum alloy of aviation standard. LAC-A1 load cells can be used to measure loads range from 1.5kg to 6kg with the measuring accuracy of 0.03% R.O.( R.O.=Rated Output)
LAC-A load cells are mainly used for electronic balances,counting scales,jewellery scales and retail scales.
LCT Single Point Load Cells have been designed such that their excellent mechanical and measurement properties can be optimally used in a wide range of applications. A Single Point Load Cells is also called Platform Load Cell.
Advantages of LCT Single Point Load Cells / Platform Load Cells:
Quick to install thanks to off-center load compensation at the factory (per OIML R60),and only one unit is sufficient to build up a scale.
Model LAB-C6A load cells are designed to this “single point”type and manufactured from high quality aluminum alloy of aviation standard. LAB-C6A load cells can be used to measure loads range from 3kg to 40kg with the measuring accuracy of 0.03% R.O.( R.O.=Rated Output)
LAB-C6A load cells are mainly used for price computing scales,counting scales,weighing scales,retail scales and bench scale.
The SC602 is a single-type load cell designed for small applications requiring high capacity. It shares the same structure as the SC601 but is shorter to minimize installation space. Despite its smaller size, it maintains a wide measuring range of up to 100 kg.
This SC602 is a single type load cell designed for compact applications that need high capacity. It follows the same structure of the SC601 but is shorter to minimize its foot print. Despite its smaller size is still maintains the wide measurement range for this load cell type with a maximum of 100kg.
LCT Planar beamload cells have been designed such that their excellent mechanical and measurement properties can be optimally used in a wide range of applications. They are designed for those who need to produce equipment with minimal overall height. They are usually implemented in sets of three or four per scale.
Advantages of LCT Planar beam load cells:
Most planar beams are not corner-adjusted. Using 3 or 4 Planar beam load cells is an alternative to a single point load cell configuration with the additional benefit of a practical unlimited platform size.
Model LAA-W7 load cells are designed to this “Planar beam”type and manufactured from high quality aluminum alloy of aviation standard. LAA-W7 load cells can be used to measure loads range from 75kg to 300kg with the measuring accuracy of 0.05% R.O.( R.O.=Rated Output)
LAA-W7 load cells are mainly used for retail scales, medical scales,personal scales,bathroom scales,airport baggage scales,postal scales and any weighing environment where space is a limiting factor.
LCT Single Point Load Cells have been designed such that their excellent mechanical and measurement properties can be optimally used in a wide range of applications. A Single Point Load Cells is also called Platform Load Cell.
Advantages of LCT Single Point Load Cells / Platform Load Cells:
Quick to install thanks to off-center load compensation at the factory (per OIML R60),and only one unit is sufficient to build up a scale.
Model LAB-B-B load cells are designed to this “single point”type and manufactured from high quality aluminum alloy of aviation standard. LAB-B-B load cells can be used to measure loads range from 3kg to 50kg with the measuring accuracy of 0.03% R.O.( R.O.=Rated Output)
LAB-B-B load cells are mainly used for price computing scales,counting scales,weighing scales,retail scales and bench scale.
50,100,200,500,1000,2000,3000kg Or Customized Single Point Weight Sensor FA524A belongs to FA524 which is from Single Point Weight Sensor category of our brand FIBOS FA5-Series. FA524A can be used to measure weight 50kg,100kg,200kg,500kg,1000kg,2000kg and 3000kg or customized capacity, its Cable size is ⌀3x4000mm or can be customized length.
100,200,500kg Or Customized Single Point Weight Sensor FA559 is a model of our brand FIBOS FA5-Series, it belongs to Single Point Weight Sensor category. FA559 can be used to measure 100kg,200kg and 500kg or customized capacity, its Creep(30min),Non-linearity and Repeatability all ≤0.2%F.S. or can be customized, its Hysteresis ≤0.3%F.S. or also can be customized.
WhatsApp us