LC3533 Bench Scales Load Cell Weighing System Aluminum Load Cell

Dimensions:

Technical Parameter:
케이센서스 스마트스토어

Dimensions:

Technical Parameter:
| Rated Load: | 50kg~1000kg | Insulation Resistance: | ≥5000MΩ |
| Sensitivity: | (2.0±0.1%) mV/V | Operating Temp.Range: | -30~+70℃ |
| Combined Error: | ±0.03% F.S | Maximum Safe Over Load: | 150%F.S |
| Creep Error(30min): | ±0.03% F.S | Ultimate Over Load: | 200%F.S |
| Zero Balance: | ±1% F.S | Recommend Excitation Vol.: | 10~12V DC |
| Temp. Effect On Zero: | ±0.02% F.S/10℃ | Maximum Excitation Vol.: | 15V DC |
| Temp. Effect On Span: | ±0.02% F.S/10℃ | Sealing Class: | IP65 |
| Input Resistance: | 385±5Ω | Element Material: | Aluminum |
| Output Resistance: | 353±2Ω | Cable: | Length=L:3m |
| Insulation Resistance: | ≥5000MΩ | Citation: | GB/T7551-2008
/ OIML R60 |
| Product name | LC3533 Bench Scales Load Cell Weighing System Aluminum Load Cell |
| Brand | SAINTBOND |
| Market | All over the world |
| Features | High precision and stable performance |
| Advantage | 0EM/ODM |
| Sample Lead Time | 5~ 40Days |
| Sample price | The price is different according to product capacity |
| Custom Design | Welcome |
| Form of sale | Factory supply |
LCT Single Point Load Cells have been designed such that their excellent mechanical and measurement properties can be optimally used in a wide range of applications. A Single Point Load Cells is also called Platform Load Cell.
Advantages of LCT Single Point Load Cells / Platform Load Cells:
Quick to install thanks to off-center load compensation at the factory (per OIML R60),and only one unit is sufficient to build up a scale.
Model LAP-B1-A load cells are designed to this “single point”type and manufactured from high quality aluminum alloy of aviation standard. LAP-B1-A load cells can be used to measure loads range from 3kg to 40kg with the measuring accuracy of 0.03% R.O.( R.O.=Rated Output)
LAP-B1-A load cells are mainly used for price computing scales,counting scales,weighing scales,retail scales and packing machinerys.
LCT Single Point Load Cells have been designed such that their excellent mechanical and measurement properties can be optimally used in a wide range of applications. A Single Point Load Cells is also called Platform Load Cell.
Advantages of LCT Single Point Load Cells / Platform Load Cells:
Quick to install thanks to off-center load compensation at the factory (per OIML R60),and only one unit is sufficient to build up a scale.
Model LAC-A9 load cells are designed to this “single point”type and manufactured from high quality aluminum alloy of aviation standard. LAC-A9 load cells can be used to measure loads range from 1kg to 2kg with the measuring accuracy of 0.03% R.O.( R.O.=Rated Output)
LAC-A9 load cells are mainly used for electronic balance,counting scales,weighing scales,retail scales,jewellery scales,kitchen scales,coffee machine and packing machine.
100,200,500kg Or Customized Single Point Weight Sensor FA559 is a model of our brand FIBOS FA5-Series, it belongs to Single Point Weight Sensor category. FA559 can be used to measure 100kg,200kg and 500kg or customized capacity, its Creep(30min),Non-linearity and Repeatability all ≤0.2%F.S. or can be customized, its Hysteresis ≤0.3%F.S. or also can be customized.
1. Stainless steel A304, laser welded and sealed
2. Protection grade: IP68, IP69K, applicable to harsh environment
3. Explosion-proof grade: Ex ia IIC T4 Ga; Ex iaD 20 T1354. Suitable for stainless steel waterproof scales and process weighing in chemical, food, and pharmaceutical industries
FA5-Series, Single Point Load Cell FA568 can be used to measure weight 50kg,100kg,200kg,300kg,500kh,1000kg, or customized capacity, its material we use Stainless steel, and we can also customize material.
LCT Single Point Load Cells have been designed such that their excellent mechanical and measurement properties can be optimally used in a wide range of applications. A Single Point Load Cells is also called Platform Load Cell.
Advantages of LCT Single Point Load Cells / Platform Load Cells:
Quick to install thanks to off-center load compensation at the factory (per OIML R60),and only one unit is sufficient to build up a scale.
Model LAK-E load cells are designed to this “single point”type and manufactured from high quality aluminum alloy of aviation standard. LAK-E load cells can be used to measure loads range from 0.3kg to 3kg with the measuring accuracy of 0.03% R.O.( R.O.=Rated Output)
LAK-E load cells are mainly used for electronic balances,counting scales,jewellery scales and retail scales.
LCT Single Point Load Cells have been designed such that their excellent mechanical and measurement properties can be optimally used in a wide range of applications. A Single Point Load Cells is also called Platform Load Cell.
Advantages of LCT Single Point Load Cells / Platform Load Cells:
Quick to install thanks to off-center load compensation at the factory (per OIML R60),and only one unit is sufficient to build up a scale.
Model LAQ-C load cells are designed to this “single point”type and manufactured from high quality aluminum alloy of aviation standard. LAQ-C load cells can be used to measure loads range from 200kg to 2000kg with the measuring accuracy of 0.02% R.O.( R.O.=Rated Output)
LAQ-C load cells are mainly used for price computing scales,counting scales,weighing scales,retail scales, bench scale, platform scales and packing machinerys.
LCT Single Point Load Cells have been designed such that their excellent mechanical and measurement properties can be optimally used in a wide range of applications. A Single Point Load Cells is also called Platform Load Cell.
Advantages of LCT Single Point Load Cells / Platform Load Cells:
Quick to install thanks to off-center load compensation at the factory (per OIML R60),and only one unit is sufficient to build up a scale.
Model LAK-H1 load cells are designed to this “single point”type and manufactured from high quality aluminum alloy of aviation standard. LAK-H1 load cells can be used to measure loads range from 0.3kg to 3kg with the measuring accuracy of 0.03% R.O.( R.O.=Rated Output)
LAK-H1 load cells are mainly used for electronic balances,counting scales,jewellery scales and retail scales.
이 SC601AC는 고용량 어플리케이션용으로 설계된 단일형 로드셀입니다. SC601과 동일한 구조를 따르지만, 최대 200kg의 더 높은 용량을 달성하기 위해 약간 더 큽니다. SC601AC는 양쪽 끝에 삼각형 모양의 구멍 3개가 있는 약간 다른 장착 방식을 가지고 있습니다. 적절한 구멍 크기와 간격은 기계 도면을 참조하십시오.
This SC601AC is a single type load cell designed for high capacity applications. It follows the same structure of the SC601 but is slightly larger in order to achieve higher capacities of up to 200kg. The SC601AC also has a slightly different mounting setup with 3 holes on each end in triangle formation. Please refer to the mechanical drawings for proper hole size and spacing
The SC602 is a single-type load cell designed for small applications requiring high capacity. It shares the same structure as the SC601 but is shorter to minimize installation space. Despite its smaller size, it maintains a wide measuring range of up to 100 kg.
This SC602 is a single type load cell designed for compact applications that need high capacity. It follows the same structure of the SC601 but is shorter to minimize its foot print. Despite its smaller size is still maintains the wide measurement range for this load cell type with a maximum of 100kg.
LCT Planar beamload cells have been designed such that their excellent mechanical and measurement properties can be optimally used in a wide range of applications. They are designed for those who need to produce equipment with minimal overall height. They are usually implemented in sets of three or four per scale.
Advantages of LCT Planar beam load cells:
Most planar beams are not corner-adjusted. Using 3 or 4 Planar beam load cells is an alternative to a single point load cell configuration with the additional benefit of a practical unlimited platform size.
Model LAA-W7 load cells are designed to this “Planar beam”type and manufactured from high quality aluminum alloy of aviation standard. LAA-W7 load cells can be used to measure loads range from 75kg to 300kg with the measuring accuracy of 0.05% R.O.( R.O.=Rated Output)
LAA-W7 load cells are mainly used for retail scales, medical scales,personal scales,bathroom scales,airport baggage scales,postal scales and any weighing environment where space is a limiting factor.
LCT Single Point Load Cells have been designed such that their excellent mechanical and measurement properties can be optimally used in a wide range of applications. A Single Point Load Cells is also called Platform Load Cell.
Advantages of LCT Single Point Load Cells / Platform Load Cells:
Quick to install thanks to off-center load compensation at the factory (per OIML R60),and only one unit is sufficient to build up a scale.
Model LAC-A load cells are designed to this “single point”type and manufactured from high quality aluminum alloy of aviation standard. LAC-A1 load cells can be used to measure loads range from 1.5kg to 6kg with the measuring accuracy of 0.03% R.O.( R.O.=Rated Output)
LAC-A load cells are mainly used for electronic balances,counting scales,jewellery scales and retail scales.
WhatsApp us