Naturoll / One-channel load cell amplifier for one sensor NF13


Model: NF13
Category: Load cell instruments
Comprehensive accuracy: 0.1%FS
Input specification: 0.4-6mv/v
Material: Aluminum ally
Protection Class: ~
Weight: ~

Share it:

One-channel load cell amplifier for one sensor NF13

Features

One-channel load cell amplifier for one sensor NF13 has a wide input range and can be equipped with most strain bridge sensors such as pressure load cell, tension/compressionload cell and torque load cell. The amplifier has high response frequency and good long-term stability. The signal channel load cell amplifier can be protected from input power reverse connection and output short circuit.

Mounting Dimension

Wiring Code

ZERO Zero adjustment gain potentiometer
SPAN Full adjustment gain potentiometer
OUTPUT V Output voltage0~10V、0~5V
I Output current4~20mA
Grounding
POWER + Voltage+
Voltage-
CH1/CH2 SIG- Signal
SIG+ Signal+
SHIELD Shielding wire
EXC- Incentive
EXC+ Incentive+

Specifications

Specifications Technique
Intput specification 0.4-6mV/v
Comprehensive accuracy 0.1%FS
Excitation voltage 5VDC±2%,100mA
Input load  1 load cells 350~1000Ω
Power supply 15-30VDC
Acquisition frequency 100HZ
Operation temp range ’-30-85