UTILCELL / SP534A SINGLE POINT LOAD CELL


Product description:

SP534A is a typical and standard alloy steel single point load cell that is with large capacity by 2t and ideal for a wide range of weighing equipment. Environmentally sealed with potting black glue compound to ensure reliability and durability. The industry standard size and mounting hole configuration makes the SP534A suitable for large-size platform by 1200*1200mm, or as a replacement for existed weighing equipment.

Besides for common applications of weighing equipment, it also can be used for force measurement on controlling.

Main Features:

• Material: Alloy steel

• Rated Capacities: 150kg~2t

• Great long-term stability.

• OIML R60, NTEP HB44, CE and RoHS certified

• IP Rating: IP67

• Suitable for single load cell big platform scales against impact and other process weighing system.

• Max platform size: 1200*1200mm

Category: Single Point


Share it:

SP534A SINGLE POINT LOAD CELL

Parameter Units Specifications
Model No. SP534A
Rated capacity (Emax) kg 150 / 250 / 500 / 1000 / 2000
Accuracy class 1) 2) C3 / C6
Min. dead load lb / kg 0
Rated output mV/V 2.0 ± 0.2
Zero balance % of Emax < ± 2
Repeatability error % of AL 3) C3: < ± 0.010 / C6: < ± 0.005
Creep; 30 min % of AL C3: < ± 0.017 / C6: < ± 0.0083
DR; 30 min % of AL C3: < ± 0.017 / C6: < ± 0.0083
Temp. effect on Min. dead load output % of Emax/℃ C3: < ± 0.0020 / C6: < ± 0.0014
Rated output 2) % of AL/℃ C3: < ± 0.0012 / C6: < ± 0.0006
Temperature range Compensated ℃ (°F) -10 ~ +40 [14 ~ 104]
Operating -40 ~ +65 [40 ~ 149]
Safe storage -40 ~ +80 [-40 ~ 176]
Excitation voltage Recommended V AC/DC 5 ~ 15
Maximum 15
Terminal resistance Excitation Ω 384 ± 5
Output 350 ± 3
Insulation resistance @50VDC > 5000
Breakdown voltage V AC > 500
Seal type / IP rating Surface potting (black silicone, coated strain gauge) / IP67
Load limit Safe % of Emax 150
Ultimate 300
Material Spring element High-quality alloy steel
Cable connector Stainless steel, electropolished
Cable Ø5.6 · 4-wire · PVC
Cable length m 3.0
Maximum platform size mm 800 × 800 / 1000 × 1000
Off-center load error (OIML R76) % of AL/cm < ± 0.0016
Fatigue life cycles @Emax > 1,000,000
Deflection at Emax mm < 0.5
Weight kg 4.0 / 4.8
Barometric pressure effect on zero Vmin/kPa < 1.0
Mounting screw Size / Grade M14 / 8.8 · M6 / 8.8
Recommended torque N·m 98.0 / 196.0
Notes:
1) Error due to combined non-linearity and hysteresis
2) Temperature effects comply with OIML R60 and NIST HB44
3) AL = Applied Load