Product description:

SP544S is a typical and standard stainless single point load cell that is compact, low capacity and ideal for a wide range of weighing equipment. Hermetically sealing ensures reliability and durability. The industry standard size and mounting hole configuration makes the SP544S is suitable for new equipment manufacturer or as a replacement for existed weighing equipment.

Main Features:

• Material: stainless steel

• Rated Capacities: 50kg~500kg

• OIML R60, NTEP HB44, CPA, CE and RoHS certified

• IP Rating: IP68 / IP69K

• Environmentally sealed by potting special black glue, also strain gauge is double-sealed with another special nanoscale coating.

• Suitable for stainless steel waterproof scales, process weighing control in chemical, food and pharmaceutical industries

• Max platform size: 300*350mm

Category: Single Point


Share it:

SP544S SINGLE POINT LOAD CELL

Parameter Units Specifications
Model No. SP544S
Rated capacity (Emax) kg 50 / 100 / 200 / 300 / 500
Accuracy class 1) 2) C3
Min. dead load kg 0
Rated output mV/V 2.0 ± 0.2
Zero balance % of Emax < ± 2
Repeatability error % of AL 3) < ± 0.010
Creep; 30 min % of AL < ± 0.017
DR; 30 min % of AL < ± 0.017
Temp. effect on Min. dead load output % of Emax/℃ < ± 0.0014
Rated output 2) % of AL/℃ < ± 0.0012
Temperature range Compensated ℃ (°F) -10 ~ +40 [14 ~ 104]
Operating -40 ~ +65 [40 ~ 149]
Safe storage -40 ~ +80 [-40 ~ 176]
Excitation voltage Recommended V AC/DC 5 ~ 15
Maximum 15
Terminal resistance Excitation Ω 384 ± 5
Output 350 ± 3
Insulation resistance @50VDC > 5000
Breakdown voltage V AC > 500
Seal type / IP rating Hermetically sealed / IP68, IP69K
Load limit Safe % of Emax 150
Ultimate 300
Material Spring element Stainless steel, electropolished
Cable connector Stainless steel, electropolished
Cable Ø5.6 · 4-wire · PVC
Cable length m 3.0
Maximum platform size mm 500 × 500 / 600 × 800
Off-center load error (OIML R76) % of AL/cm < ± 0.0016
Fatigue life cycles @Emax > 1,000,000
Deflection at Emax mm < 0.5
Weight kg 2.1
Barometric pressure effect on zero Vmin/kPa < 1.0
Mounting screw Size / Grade M8 – 8.8
Recommended torque N·m 40.0
Notes:
1) Error due to combined non-linearity and hysteresis
2) Temperature effects comply with OIML R60 and NIST HB44
3) AL = Applied Load