R119 Barrel Tension And Compression Load cell
Dimension

Parameters
| Specifications |
Technique
|
| Capacity |
0.05,0.1,0.2,0.5,1,2,5,10,20,50,100 kN
|
| Sensitivity |
2.0 ± 10 % mV / V
|
| Zero Balance |
± 0.05 mV / V
|
| Non-linearity |
0.1% F.S.
|
| Hysteresis Error |
0.1% F.S.
|
| Repetition |
0.1% F.S.
|
| Creep (30 min) |
0.05% F.S.
|
| Temp. Effect on sensitivity (TKc) |
0.05% F.S. / 10 ℃
|
| Temp. Effect on zero balance (TKo) |
0.05% F.S. / 10 ℃
|
| Input Resistance |
385 ± 10 Ω
|
| Output Resistance |
350 ± 10 Ω
|
| Insulating Resistance |
≥5000 MΩ / 100VDC
|
| Excitation Voltage |
5 ~ 15 V
|
| Max. Excitation Voltage |
20 V
|
| Compensation Range |
-10 ~ 60 ℃
|
| Service Temperature Range |
-20 ~ 80 ℃
|
| Limit load (E L) |
150% F.S.
|
| Breaking load (E d) |
200% F.S.
|
| Cable Size |
φ3 × 4000 mm
|
| Weight (G), approx. |
0.3 kg
|
| Material (Measuring element) |
Stainless steel
|
| IP Class |
IP66
|
Features and Applications
Low height, small deformation, small size and large range;
stainless steel material;
High dynamic response frequency;
Protection grade: IP65 can be customized;
Automotive press assembly, automated assembly, 3C product testing, new energy product assembly, medical testing, robotics,
Mold assembly and other industrial test, measurement and control systems
Load Direction

Wiring Code