ATO / ATO-LCS-DYLY-106 / S type Micro Load Cell


S type load cell can bear both tension and pressure, with good stability, good output symmetry, high accuracy, low temperature drift, compact structure and complete specifications. Micro load cell is suited to use in restricted spaces.


Share it:

ATO-LCS-DYLY-106 Micro Load Cell, S type, 1kg/2kg/3kg/10kg to 50kg

After purchasing one ATO load cell, you can buy a special digital panel meter to obtain readings directly, or buy a transmitter to output standard signal to PLC, DCS and other systems. Customized output signal is 0-5V, 0-10V, or 4-20mA.

Note: The load cell cannot be connected to both the transmitter and the controller at the same time — only one can be selected.

Tension and compression load cells have capacity range from 1kg, 2kg, 3kg, 10kg to 50kg. Load cell capacity can be customized according to customer requirements. It is able to measure both tensile and compressive forces, and it offers good hardenability and strong resistance to mechanical fatigue, quite durable for heavy-duty use.

Specification

Model ATO-LCS-DYLY-106
Weight 0.06kg
Capacity Range * 0kg~50kg
Matched Display Controller ATO-DDC5-CHB (Click it to the controller page)
Matched Transmitter ATO-LCTR-OA (Click it to the transmitter page)
Accuracy 0.05%F.S (linearity + hysteresis + repeatability)
Sensitivity 2.0±0.05mV/V (Low range variations may differ)
Frequency Response 8 kHz
Creep ±0.03%F.S/30min
Zero Output ±1%F.S
Temperature Effect on Zero ±0.03%F.S/10℃
Temperature Effect on Output ±0.03%F.S/10℃
Operating Temperature -20℃~+80℃
Input Impedance 350±20Ω
Output Impedance 350±5Ω
Insulation Resistance ≥5000MΩ
Safety Overload 150%F.S
Bridge Voltage (excitation voltage) DC 5-15V, suggest DC 10V
Material Alloy steel
Protection Class IP67
Cable Length 2m
Wiring EXC+: Red, EXC-: Black, SIG+: Green, SIG-: White

Feature

Micro load cell s type 1kg to 50kg feature

  • Durable Alloy Construction: Made of high-quality 42CrMo alloy steel with rounded edges and sandblasted finish for longevity.
  • Compact & High Precision: Micro load cell small size with high accuracy, suitable for various weighing applications.
  • Industrial-Grade Strain Gauge: Ensures high measurement precision and operates in extreme environments like high/low temperatures and high pressure.
  • Bidirectional Force Measurement: S type load cell supports both tension and compression testing for versatile applications.
  • Threaded Hole Design: Top and bottom threaded holes for easy installation in belt scales, hopper scales, and batching systems.
  • Stable Signal Transmission: 3mm diameter shielded signal cable with strong anti-interference capability.

Dimension (unit: mm)

Micro load cell s type 1kg to 50kg dimension
Note: Length of M6 screw is 6mm.

Wiring Method

Load cell wiring method

Tips: How to judge lead wire of load cell?
The output resistance of the load cell is generally 350Ω, 480Ω, 700Ω, 1000Ω. The input terminal will be conducted with temperature and sensitivity compensations. Therefore, the resistance of the input terminal will be 20~100Ω higher than that of the output terminal. Therefore, if the multimeter is used to measure the resistance value, the input and output terminals can be judged. Normally, the colors of the input and output terminals are red, black, green and white. They are respectively marked as EXC+, EXC-, SIG+ and SIG-.