CALT / DYLY-109 / S Type 로드셀


  • Capacity: 0-10kg
  • Sensitivity: 1.0~2.0 mV/V
  • Non-linearity 0.1% F.S.
  • Repeatability 0.05% F.S.
  • Material Stainless steel with nickel plated
  • Bi-directional tension and compression
  • Can be customized

Share it:

S Type Load Cells DYLY-109

Characteristic and Application fields

It has the advantages of bi-directional tension and compression, compact structure, high comprehensive precision, good long-term stability and nickel plating on the surface of high-quality alloy steel.

Universal materisl testing machine, hopper scale, hook scale, packaging scale, belt scale, plug-in force tester and othere tension and pressure testing instruments as well as automation equipment and testing field.

Dimension(mm)

Capacity (kg) 0.5  1  2  5  10

Wiring diagram

Force diagram

Technical parameter

Parameter Unit Technical

Specifications

Parameter Unit Technical

Specifications

Sensitivity mV/V 1.0-2.0 Temperature coefficient of sensitivity ≤%F·S

/10℃

±0.05
Nonlinear ≤%F·S ±0.1 Operating temperature range -20℃~+80℃
Hysteresis ≤%F·S ±0.05 Input resistance Ω 350Ω
Repeatability ≤%F·S ±0.05 Output Resistance Ω 350Ω
Creep ≤%F·S/30min ±0.05 Safe Overload ≤%F·S 150% F·S
Zero output ≤%F·S ±2 Insulation resistance ≥5000MΩ(100VDC)
Zero temperature

coefficient

≤%F·S/10℃ ±0.05 Excitation voltage V 5V-15V