CALT / GDS60 / 병렬 출력 고정밀 광전 싱글턴 앱솔루트 엔코더


  • High-precision photoelectric single-turn absolute encoder
  • Detection method: photoelectric detection
  • Operating voltage: 10…30Vdc polarity protected
  • Output signal: Parallel output (pure binary, Gray code or Gray remainder)
  • Programmable, intelligent absolute encoder, professional setting software, user-friendly operation
    With setting line, easy to install and debug
  • Resolution: ≤18 bits, up to 262144 lines (order selection)
  • Accuracy: ±0.01°
  • Outer diameter 60mm, inner hole/shaft diameter 6-15mm optional
  • Protection class: shell IP67 shaft IP65
  • Vibration and shock: 20g, 10~2000Hz; 100g, 6ms
  • Allowable speed: 6000 rpm
  • Software and hardware can be customized according to actual needs

Share it:

Parallel output high-precision photoelectric single-turn absolute encoder GDS60 series

Specifications

Mechanical parameters Electrical parameters
maximum speed 6000 rpm Operating Voltage 10-30Vdc (5Vdc can be customized)
Spindle load Axial 40N, Radial 100N current consumption < 300mA (24Vdc) no load
impact resistance 1000m/s²(6ms), equal to 100g output signal 18-bit synchronous parallel signal (pure binary, Gray code)
Anti-vibration 200m/s²(10-2000Hz), equal to 20g Linear resolution 1/262144FS
Allow axial play ±1.5mm IP Class IP65 or 68
Allow radial runout ±0.2mm positioning accuracy 0.01º
external structure 60mm OD, solid shaft, blind hole shaft Operating temperature -40℃~85℃
Connection Type 30 core shielded cable or aviation plug Storage temperature -40℃~85℃

 

reliable and patented

l Strong bearing structure with Safety-Lock TM design, which can provide higher vibration resistance and installation error resistance

l IP68 protection grade and wide operating temperature range -40℃…+85℃

l Patented mechanical gear technology, with permanent power-off memory function

performance optimization

l High precision, data refresh rate of location data ≤ 4us

l Direct reading through I/O port

l International standard SSI signal format

Wiring diagram

Black/1 20 orange/3 28 Ash/3 216 brown/3 224 Note:

1. Parallel output reference voltage, voltage drop of <2V per bit is normal. Please use short-circuit with the positive (brown) power supply.

2. Set: connect to 24V + 1 second to set the current value to zero.

3. Forward and reverse: counterclockwise data increase when connected to 24V+

4. Parallel output maximum 50mA per bit

5 Active high.

Black/2 21 Purple/1 29 blue/2 217
Black/3 22 Purple/2 210 blue/3 218
Green/1 23 Purple/3 211 Red/2 219 Red/1 KVCC

Note 1

Green/2 24 yellow/1 212 Red/3 220 Ash/1 Set   Note 2
Green/3 25 yellow/2 213 white/2 221 Brown/1 10-30Vdc
Orange/1 26 yellow/3 214 white/3 222 white/1 GND 0V
Orange/2 27 Ash/2 215 brown/2 223 blue/1 Forward and reverse Note 3

Mechanical dimension drawing

 

 

Clamping synchro flange (optional for cable output or plug output)

Synchronous flange/servo flange (cable output or plug output optional)

Blind Hole/Half Through Hole Flange (Cable output or plug output optional)

output signal
The output is a parallel push-pull output signal, which is connected to the input module (I/O) of the PLC as shown in the figure below: