Interface / T1 flange dynamic torque


Measuring range: 50Nm~1000Nm

Accuracy: ±0.05%FS


Share it:

T1 flange dynamic torque

Technical parameters

Category Parameter Standard Type (标准型) Enhanced Type (增强型)
Accuracy Class ( MAX ERROR )
Combined Accuracy — %FS ± 0.15 ± 0.05
Repeatability — % ± 0.02 ± 0.005
Temperature
Temp. Effect on Zero (Max) ± 0.02 %RO/°C ± 0.008 %RO/°C
Temp. Effect on Sensitivity (Max) ± 0.01 %RO/°C ± 0.005 %RO/°C
Compensated Temp. Range +5 to +45 °C +5 to +45 °C
Operating Temp. Range 0 to 60 °C 0 to 60 °C
Electrical
Output Signal — VDC ± 5 ± 5
Bandwidth — Hz 3 kHz (-3dB) 3 kHz (-3dB)
Sampling Rate 10 kHz 10 kHz
Calibration Signal — %FS 100 100
Operating Voltage — VDC 12 to 18 12 to 18
Operating Current — mA < 100 < 100
Electrical Connection 12-pin 12-pin
Resolution 16-bit 16-bit
Mechanical
Safe Overload — %RO 200 200
Cyclic Rated Load — %RO ± 70 peak ± 70 peak
Ultimate Overload — %RO 300 300
Max Speed — rpm 13.6K – See Table 13.6K – See Table

Dimensions

T1 flange dynamic torque

T1 flange dynamic torque

T1 flange dynamic torque