Santwell / LFM / 스포크형 로드셀


Ningbo Santwell Import & Export Co., Ltd comes here today with the great news that we have successfully developed Load cells, Subminiature force transducers, miniature load cells, Intelligent load cells.It is a kind of new product made by state-of-the-art technologies. Force Sensors & Load Cells has passed a series of international quality assurance system and product safety certification . Since our inception, Ningbo Santwell Import & Export Co., Ltd have been striving forward with the aim of being a leading company in the globe. We will focus more on improving our R&D capabilities and upgrading technologies in order to develop more creative products, therefore leading the industry trends and keeping us competitive in the market. of the most leading brands in the future.

Model Number: LFM Place of Origin: Zhejiang, China
Brand Name: Santwell Usage: PRESSURE SENSOR
Theory: Resistance Sensor Output: Analog SENSOR
Description: shear beam load cell Rated Load: 100t
Sensitivity: 2.0000±0.002mv/v Total Error: ±0.05%F.S
Creep(30 minutes): ±0.02%F.S Recommended Excitation Voltage: 5V-18V(AC or DC)
Maximum Excitation Voltage: 24V(AC or DC) Zero Balance: ±1%F.S
Insulation Impedance: ≥5000MΩ Safe Overload: ±150%F.S
UItimate Overload: ±200%F.S Application: Force measurement equipment

 

 

 

 

 

 

 

 

 

 


Share it:

Measurement Equipment spoke load cell Pancake Tension 100 Ton load cell LFM with good performance and reliable quality are created by conforming to the development trend of the industry, integrating internal superior resources, and adopting the industry’s cutting-edge manufacturing technology and production process.Therefore,It has been proved that the product can be applied to Force Sensors & Load Cells.

Shipping: Support Sea freight · Land freight

Customization: Customized logo (Min. Order: 100 Pieces),Customized packaging (Min. Order: 300 Pieces),Graphic customization (Min. Order: 100 Pieces)

Technical Parameter

Rated Load
T
100
Sensitivity
mV/V
2.0000±0.002
Total Error
%F.S
±0.05
Creep(30minutes)
%F.S
±0.02
Recommended Excitation Voltage
V
5 ~18(AC or DC)
Maximum Excitation Voltage
V
24 (AC or DC)
Zero Balance
%F.S
±1
Input Impedance
Ω
775±10
Output Impedance
Ω
700±5
Insulation Impedance
≥5000
Safe Overload
%F.S
150
Ultimate Overload
%F.S
200
Operating Temperature Range
(-30~+70)
Compensated Temperature Range
(-20~+60)
Temperature Effect On Load
±0.02%F.S/10
Temperature Effect On Zero
±0.02%F.S/10
Construction
Alloy steel
Protection Class
IP67&IP68
Citation
GB/T7551-2008/OIML R60
Mode of Connection
Input+E:Red
Input-E:Black
Output+S:Green
Output-S:White