UT142 Flat Membrane Box Load Cell
![]() |
Product FeaturesSL127 planar force sensor has a low profile, upper and lower flange structure, high precision, good strength, easy installation, and good output symmetry. |
Technical Specifications
| Specification | Technical Indicators |
| Capacity | 10,20,50,100,200,500kg |
| Rated Output | 1.0±10%mV/V |
| Zero Balance | ±0.03%F.S |
| Creep | ≤0.2%F.S. |
| Non-Linearity | ≤0.5%F.S. |
| Hysteresis | ≤0.3%F.S. |
| Repeatability | ≤0.2%F.S. |
| Input Impedance | 700±20Ω |
| Output Impedance | 700±10Ω |
| Temp. effect on output | 0.1%F.S./10℃ |
| Temp. effect on zero | 0.1%F.S./10℃ |
| Insulation Resistance | ≥5000MΩ/100V(DC) |
| Recommended Excitation | 5~15V |
| Maximum Excitation | 20V |
| Compensated Temp Range | -10~60℃ |
| Operating Temp Range | -20~70℃ |
| Safe Overload | 150% F.S. |
| Ultimate overload | 200% F.S. |
| Cable Size | φ3X3000mm |
| Material | Stainless steel |
Product Dimensions
Installation size

Load Direction

Wiring Diagram

Accurate measurement with matching display