| Specification | Value | |||||
| Maximum capacity (Emax) | t | 0.5/ 1/ 2/ 2.5/ 3/ 4/ 5/ 6/ 7.5 | ||||
| klb | 1/1.5/2/2.5/3/4/5/7.5/10/20 | |||||
| Accuracy class | C3 | C4 | C5 | A5M | B10M | |
| Approvals | OIML R60 C3 | OIML R60 C4 | OIML R60 C5 | III5000 Multiple | III10000 Multiple | |
| Maximum number of load cell intervals (nLC) | 3000 | 4000 | 5000 | 5000 | 10000 | |
| Ratio of minimum LC verification interval Y = Emax/vmin | 10000 | 14000 | 18000 | 15000 | 10000 | |
| Combined error | %FS | ±0.020 | ±0.018 | ±0.010 | ±0.026 | ±0.050 |
| Creep | %FS/30min | ±0.016 | ±0.012 | ±0.010 | ±0.017 | ±0.040 |
| Temperature effect on sensitivity | %FS/10℃ | ±0.011 | ±0.009 | ±0.008 | ±0.013 | ±0.040 |
| Temperature effect on zero | %FS/10℃ | ±0.015 | ±0.010 | ±0.007 | ±0.014 | ±0.020 |
| Output sensitivity ( = FS ) | mV/V | 3.0±0.003 2.0±0.002 | ||||
| Terminal resistance/ input | Ω | 350 ± 3.5 | ||||
| Terminal resistance/ output | Ω | 350 ± 3.5 | ||||
| Insulation impedance | MΩ | ≥5000 (at 50V DC) | ||||
| Zero balance | %FS | ±1.0 | ||||
| Compensated temperature | ℃ | -10~+40 | ||||
| operating temperature | ℃ | -35~+70 | ||||
| Excitation/ recommended voltage | V | 5~12 (DC) | ||||
| Excitation/ maximum | V | 18 (DC) | ||||
| Safe overload | of Emax | 150% | ||||
| Ultimate overload | of Emax | 300% | ||||
| Recommended torque on fixation | N.m | M12:100 M18:200 M24:700 | ||||
| Ingress Protection (according to EN 60529) | IP67 | |||||
| ATEX classification (optional) | Operating temperature ℃ -20~+40 | |||||
| II1G Ex ia II C T4 II1D Ex iaD 20 T73°C II3G Ex nL IIC T4 | ||||||
| “S1″Output Sensitivity is 2.0±0.002MV/V | ||||||