Right / F223 / Load Cell for Scale


Mainly used for auto press assembly, automated assembly, 3C product testing, new energy, product assembly;
Medical testing, robotics, mold assembly, and other industrial test, measurement, and control systems have high dynamic response frequencies.

Material: stainless steel
definition: Small size, Large range


Share it:

F223 Load Cell for Scale

Dimension

F223 Installation drawings

Parameters

Specifications

Technique

Capacity

5,10,15 t

Sensitivity

2.0 ± 0.002 mV / V

Zero Balance

± 0.05 mV / V

Non-linearity

0.02% F.S.

Hysteresis Error

0.02% F.S.

Repetition

0.01% F.S.

Creep (30 min)

0.02% F.S.

Temp. Effect on sensitivity (TKc)

0.002% F.S. / 10 ℃

Temp. Effect on zero balance (TKo)

0.002% F.S. / 10 ℃

Input resistance

380 ± 20 Ω

Output resistance

350 ± 10 Ω

Insulating Resistance

≥5000 MΩ / 100VDC

Excitation Voltage

5 ~ 15 V

Max. Excitation Voltage

20 V

Compensation Range

-10 ~ 40 ℃

Service Temperature Range

-20 ~ 65 ℃

Limit load (E L)

150% F.S.

Breaking load (E d)

200% F.S.

Cable size

φ5 × 4000 mm

Weight (G), approx.

0.5 kg

Material (Measuring element)

Stainless steel

IP Class

IP66

Features and Applications

Low height, small deformation, small size, large range

Suitable for various environments, IP 65, can be customized

Automotive press assembly, automated assembly, 3C product testing, new energy product assembly, medical testing, robotics,

Mold assembly and other industrial test, measurement and control systems

High dynamic response frequency

 

Load Direction

t702B-3

Wiring Code

Wiring regulations