T717 Stainless Steel Load Cell
Dimension

Parameters
|
Specifications
|
Technique
|
|
Capacity
|
50,100,200,300,500,1000 kg
|
|
Sensitivity
|
2.0 ± 0.002 mV / V
|
|
Zero Balance
|
≤1% F.S.
|
|
Non-linearity
|
≤0.017 % F.S.
|
|
Hysteresis Error
|
≤0.017 % F.S.
|
|
Repetition
|
≤0.01% F.S.
|
|
Creep (30 min)
|
≤0.017 % F.S.
|
|
Temp. Effect on sensitivity (TKc)
|
≤0.002 % F.S. / 10 ℃
|
|
Temp. Effect on zero balance (TKo)
|
≤0.002 % F.S. / 10 ℃
|
|
Input Resistance
|
380 ± 20 Ω
|
|
Output Resistance
|
350 ± 10 Ω
|
|
Insulating Resistance
|
≥5000 MΩ / 100VDC
|
|
Excitation Voltage
|
5 V
|
|
Max. Excitation Voltage
|
15 V
|
|
Compensation Range
|
-10 ~ 40 ℃
|
|
Service Temperature Range
|
-40 ~ 65 ℃
|
|
Limit load (E L)
|
150% F.S.
|
|
Breaking load (E d)
|
300% F.S.
|
|
Cable size
|
φ6.3 × 2500 mm
|
|
Weight (G), approx.
|
0.9 kg
|
|
Material (Measuring element)
|
Stainless Steel
|
|
IP Class
|
IP67
|
Features and Applications
Stainless steel material, strong stability
High comprehensive sensitivity and compact structure
Four corner deviations have been compensated
Good long-term stability
Mainly used for stainless steel waterproof scales, process weighing in the chemical waterproof pharmaceutical industry
Load Direction

Wiring Code