R118B Tension And Compression Bidirectional Load Cell
Dimension

Parameters
| Specifications |
Technique
|
| Capacity |
0.1,0.2,0.5,1,2,3,5,10 T
|
| Sensitivity |
1.5 ± 10 % mV / V
|
| Zero Balance |
± 2% F.S.
|
| Non-linearity |
0.2% F.S.
|
| Hysteresis |
0.2% F.S.
|
| Repetition |
0.1% F.S.
|
| Creep (30 min) |
0.03% F.S.
|
| Temp. Effect on sensitivity (TKc) |
0.02% F.S. / 10 ℃
|
| Temp. Effect on zero balance (TKo) |
0.02% F.S. / 10 ℃
|
| Input Resistance |
780 ± 10 Ω
|
| Output Resistance |
700 ± 5 Ω
|
| Insulating Resistance |
≥5000 MΩ / 100VDC
|
| Excitation Voltage |
5 ~ 12 V
|
| Max. Excitation Voltage |
15 V
|
| Compensation Range |
-10 ~ 40 ℃
|
| Service Temperature Range |
-20 ~ 70 ℃
|
| Limit load (E L) |
120% F.S.
|
| Breaking load (E d) |
150% F.S.
|
| Cable Size |
φ4 × 4000 mm
|
| Material (Measuring element) |
Stainless steel / alloy steel
|
| IP Class |
IP66
|
Features and Applications
Flange sensor;
Stainless steel / alloy steel material;
Tension and compression bidirectional, range can be customized;
Medical testing, robotics, mold assembly and other industrial test, measurement and control systems;
Also suitable for various industrial weighing systems such as testing machines, truck scales, hopper scales, etc .;
Load Direction

Wiring Code