Xjcsensor / X-100P Flat Embedded Diaphragm Type / Pressure Sensor/Pressure Transmitter


Feature
  • Range:-100kpa-0 & 20kpa-35bar.
  • Hygienic design, complying with CIP-SIP cleaning requirements.
  • Multiple Process connection optional.
  • Multiple output signals optional.
  • Multiple electrical connections.
  • Superior long term stability, strong antiinterference ability.

Share it:
Technical Parameter
Product Performance
Long-Term Stability ±0.2%FS/year(Not cumulative)
Accuracy ±0.25%FS, ±0.5%FS(Optional)
P201 Temp. Effect 1.5FS/100℃
Comp. Temp. -20℃~80℃
Working Temp.
Non-Display -40℃~85℃
LCD -20℃~70℃
Measuring Medium Temp.
Filled Silicone Oil -40℃~125℃
-40℃~250C(Adding connectors)
Zero Error ±1%FS
Span Error ±1%FS
Response Time ≤30ms
Fatigue Life More than 100million designs
Physical Characteristics
Pressure Interface See Ordering Guide
P201 Contact Parts SS316L
Electrical Interface See Ordering Guide
Shell Material SS304
Shell Protection IP65/IP67
Shock EC 68-2-27 procedure I
Vibration 10g, 25-2000Hz
Weight About 200g
Environmental Data
Certification CE, RoHS
Voltage Output
Output (3-wire) Min OV to max 10V
Power Supply Over full range output 4V, max 30Vdc
Current Output
Output (2-wire)  4-20mA, 4-20mA+HART 2-wire
Power Supply 10-30Vdc
Range Proof Pressure(xFS) Burst Pressure(xFS)
Kpa/bar X-100P X-100P
Vacuum 5.0xFS 10.0xFS
40~100kpa 2.0xFS 5.0xFS
200kpa~35bar 2.0xFS 3.0xFS
Modbus-RTU
Type Terminal Current signal Voltage signal Voltage signal RS485 Cable Colour
M12*1 1 +ve Supply +ve Supply +ve Supply +ve Su pply Brown
2 OV Com -ve Output -ve Supply White
3 tve Output +ve Output +ve Output A+ Blue
4 -ve Sup pply B- Black
DIN 1 +ve Supply +ve S upply +ve Sup pply +ve Supply Red
2 +ve Output +ve Output -ve Sup ply -ve Supply Black
3 OV Com +ve O utput A+ Blue
GND -ve Out put B- White
Dimension & Capacity

pic-1

Application

Flat embedded diaphragm type

Ordering Guide

Model: X-100P-①②③④⑤⑥

Attention Range Process connection Output Electrical connection Radiator Accuracy
1. 4PIN Standardized 2m Cable Line

2. Direct lead with 1 m cable

3. Voltage output is not optional with 8L

4. Can only be selected with 2D8L

5. With”*”,please contact the technician

Range

K=kPa

B=barM=MPa

2G*=G1/4 *

4G=G1/2

6G=G3/4

8G=G1″”

20M=M20x1.5XX*=Other *”

4A=4~20mA

4AX=4-20mA+LCD

With Display

10V=0~10V

2D=DIN43650

Hirschmann

4P=4pin

xE=Direct lead x meter

8L=2088

Aluminium shell

=135℃

No radiator

5S=150℃

5 radiators

10S=200℃

10 radiators

=±0.5%FS

2=±0.25%FS